文献速递腹部技术与安全MR

3T扩散加权MRI在结直肠癌肝转移化疗后疗效评估中的应用:ADC值与组织学肿瘤消退分级的相关性

3T diffusion-weighted MRI in the response assessment of colorectal liver metastases after chemotherapy: Correlation between ADC value and histological tumour regression grading.
PubMed 文献 · Eur J Radiol · 2017-03-29

本研究纳入35例结直肠癌肝转移患者,术前化疗后行3T DW-MRI(b值0、150、500、1000、1500s/mm²),对106个肝转移灶测量肿瘤整体(ADCe)、周边(ADCp)和中心(ADCc)的ADC值,并与术后组织病理学肿瘤消退分级(TRG)进行相关性分析。结果显示TRG1和TRG2病灶的ADCe和ADCp值显著高于TRG3、TRG4和TRG5(p<0.0001),ADC值与TRG分级呈负相关(Spearman相关系数-0.568、-0.542、-0.554)。

要点

  • TRG1和TRG2病灶的ADCe和ADCp值显著高于TRG3、TRG4和TRG5(p<0.0001)。
  • ADCe、ADCp和ADCc值在TRG分级间差异显著(p<0.0001),且与TRG分级呈负相关。
  • 测量ADC时需分别勾画肿瘤整体、周边和中心ROI,不同区域ADC值与TRG相关性不同。

核心结论

  • 3T DW-MRI的ADC值与结直肠癌肝转移术前化疗后的组织学TRG显著相关。

研究设计与样本

  • 回顾性研究,纳入35例结直肠癌肝转移患者,共分析106个肝转移灶(直径>1cm);使用3T MRI(GE DISCOVERY MR750; GE Healthcare)行单次激发自旋回波平面DW-MRI,b值为0、150、500、1000、1500s/mm²,由两名放射科医生共同勾画三个ROI(肿瘤整体、周边、中心)计算ADC值;以术后组织病理学TRG(分为TRG1至TRG5五级)为参考标准;统计分析基于病灶采用单因素方差分析。

诊断标准与关键数值

  • TRG1、TRG2、TRG3、TRG4和TRG5分别见于4、14、36、35和17个病灶;ADCe和ADCp值在TRG1(分别为2.40±0.12×10⁻⁹m²/s和2.28±0.26×10⁻⁹m²/s)和TRG2(分别为1.40±0.31×10⁻⁹m²/s和1.44±0.35×10⁻⁹m²/s)显著高于TRG3(分别为1.16±0.13×10⁻⁹m²/s和1.01±0.18×10⁻⁹m²/s)、TRG4(分别为1.10±0.26×10⁻⁹m²/s和0.97±0.24×10⁻⁹m²/s)和TRG5(分别为0.93±0.17×10⁻⁹m²/s和0.82±0.28×10⁻⁹m²/s)(p<0.0001);ADCe、ADCp和ADCc值与TRG分级的Spearman相关系数分别为-0.568、-0.542和-0.554。

临床应用与阅片要点

  • 作者认为3T DW-MRI的ADC值与结直肠癌肝转移术前化疗后的组织学TRG显著相关,测量时需分别评估肿瘤整体、周边和中心区域。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of the study was to correlate the apparent diffusion coefficient (ADC) values of diffusion-weighted MR imaging (DW-MRI) by 3T device with the histological tumour regression grading (TRG) analysis of colorectal liver metastases after preoperative chemotherapy.

MATERIALS AND METHODS: Our study included thirty-five patients with colorectal liver metastases who had undergone MRI by 3T device (GE DISCOVERY MR750; GE Healthcare) after preoperative chemotherapy. DW-MRI was performed using a single-shot spin-echo echo-planar sequence with multiple b-values (0, 150, 500, 1000, 1500s/mm2), thus obtaining an ADC map. For each liver lesion (more than 1cm in diameter) the fitted ADC values were calculated by two radiologists in conference and three ROIs were drawn: around the entire tumour (ADCe), at the tumour periphery (ADCp) and at the tumour center (ADCc). All ADC values were correlated with histopathological findings after surgery. Hepatic metastases were pathologically classified into five groups on the basis of TRG. Statistical analysis was performed on a per-lesion basis utilizing the one-way analysis of variance (ANOVA). This retrospective study was approved by our institutional review board; written informed consent was obtained from all patients.

RESULTS: A total of 106 colorectal liver metastases were included for image analysis. TRG1, TRG2, TRG3, TRG4 and TRG5 were observed in 4, 14, 36, 35 and 17 lesions, respectively. ADCe and ADCp values were significantly higher in lesions classified as TRG1 (2.40±0.12×10-9m2/s and 2.28±0.26×10-9m2/s, respectively) and as TRG2 (1.40±0.31×10-9m2/s and 1.44±0.35×10-9m2/s), compared to TRG3 (1.16±0.13×10-9m2/s and 1.01±0.18×10-9m2/s), TRG4 (1.10±0.26×10-9m2/s and 0.97±0.24×10-9m2/s), and TRG5 (0.93±0.17×10-9m2/s and 0.82±0.28×10-9m2/s). ADCe, ADCp and ADCc values were significantly different in TRG classes (p<0.0001). Statistical correlations were found between the ADCe, ADCp, ADCc values and the TRG classes (Spearman correlation coefficient were -0.568, -0.542 and -0.554, respectively).

CONCLUSION: Our study showed a significant correlation between ADC values of 3T DW-MRI and histological TRG of colorectal liver metastases after preoperative chemotherapy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Donati F, Boraschi P, Pacciardi F, et al. 3T diffusion-weighted MRI in the response assessment of colorectal liver metastases after chemotherapy: Correlation between ADC value and histological tumour regression grading. Eur J Radiol. 2017. PMID: 28629572. doi:10.1016/j.ejrad.2017.03.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。