文献速递腹部CT

平扫计算机断层扫描鉴别胃异尖线虫病与非异尖线虫病

Distinguishing gastric anisakiasis from non-anisakiasis using unenhanced computed tomography.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

本研究纳入56例异尖线虫病和74例非异尖线虫病伴胃壁增厚的急诊平扫CT病例,由两名放射科医生评估5项CT征象的可重复性,并开发异尖线虫病诊断评分(ADS)及预测切点(ADP)。结果显示除腹水外各征象在异尖线虫病组更常见,ADP敏感度91%、特异度84%、准确率87%,AUC为0.902(p<0.05)。

要点

  • 「粗大低密度胃壁增厚」诊断异尖线虫病的敏感度最高(98%)。
  • 「胃壁增厚累及两个以上分区」诊断异尖线虫病的特异度最高(80%)。
  • ADP预测异尖线虫病的敏感度91%、特异度84%、准确率87%,AUC为0.902(p<0.05)。

核心结论

  • 平扫CT征象可用于鉴别胃异尖线虫病与非异尖线虫病胃部病变,且可重复性充分。

研究设计与样本

  • 研究纳入56例异尖线虫病和74例非异尖线虫病伴胃壁增厚的急诊平扫CT病例,两名放射科医生独立评估CT征象可重复性,并共识评估诊断效能。

关键影像表现/征象

  • 评估的CT征象包括「环周胃壁增厚」、「胃壁增厚累及两个以上分区」、「粗大低密度胃壁增厚」、「胃周脂肪密度增高」和「腹水」。
  • 除「环周胃壁增厚」的κ值为0.499外,其余征象的κ值均在0.6至0.8之间,可重复性为中等程度一致。
  • 除腹水外,其余CT征象在异尖线虫病组中的出现频率均显著高于非异尖线虫病组。

诊断标准与关键数值

  • 「粗大低密度胃壁增厚」诊断异尖线虫病的敏感度为98%,为所有征象中最高。
  • 「胃壁增厚累及两个以上分区」诊断异尖线虫病的特异度为80%,为所有征象中最高。
  • 基于异尖线虫病诊断评分(ADS)的异尖线虫病诊断预测(ADP)敏感度为91%、特异度为84%、准确率为87%。
  • ADP的曲线下面积(AUC)为0.902(p<0.05)。

临床应用与阅片要点

  • 在急诊平扫CT上遇到胃壁增厚时,可观察有无「粗大低密度胃壁增厚」及「胃壁增厚累及两个以上分区」等征象。
  • 除腹水外,上述CT征象在异尖线虫病组更常见,可辅助鉴别诊断。
  • 「环周胃壁增厚」的可重复性为中等程度一致(κ=0.499),判读时需注意。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to assess the diagnostic performance of unenhanced computed tomography (CT) for distinguishing gastric anisakiasis from non-anisakiasis gastric conditions and the reproducibility of CT findings.

METHODS: Fifty-six anisakiasis and 74 non-anisakiasis cases with gastric wall thickening on urgent observation using unenhanced CT were included. Using a κ analysis, two radiologists independently assessed the reproducibility of CT findings, including "circumferential gastric wall thickening," "gastric wall thickening extending more than two segments," "bulky and low-density gastric wall thickening," "increase in peri-gastric fat density," and "ascites." An anisakiasis diagnostic score (ADS) was developed for this study and was used to quantitatively evaluate the CT findings. An anisakiasis diagnostic prediction (ADP) with an appropriate cutoff value was used to further evaluate the ADS. Two radiologists reassessed the findings in consensus to determine the sensitivity, specificity, and accuracy of the CT findings, including the ADP and ADS area under the curve (AUC).

RESULTS: Considering reproducibility, a substantial agreement (0.6 < κ < 0.8) was achieved for all findings except "circumferential gastric wall thickening" (κ = 0.499), whereas for diagnostic performance, all findings except ascites were significantly more frequent among the anisakiasis cases. "Bulky and low-density gastric wall thickening" had the highest sensitivity (98%), whereas "gastric wall thickening extending more than two segments" had the highest specificity (80%). The ADP sensitivity, specificity, and accuracy were 91%, 84%, and 87%, respectively. The AUC was 0.902 (p < 0.05).

CONCLUSIONS: Unenhanced CT findings are useful for distinguishing anisakiasis from non-anisakiasis gastric conditions with sufficient reproducibility.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ashida H, Igarashi T, Morikawa K, et al. Distinguishing gastric anisakiasis from non-anisakiasis using unenhanced computed tomography. Abdom Radiol (NY). 2017. PMID: 28643138. doi:10.1007/s00261-017-1214-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。