文献速递腹部技术与安全CT

双源双能量CT成像评估正常人肝脏内铁的空间分布

Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging.
PubMed 文献 · Invest Radiol · 2017-01-01

本研究通过体模实验建立双源双能量CT铁浓度转换因子(0.15 mg Fe/mL每HU),回顾性分析37例肝功能正常患者的肝脏铁浓度。全肝平均铁浓度范围0.0至2.91 mg Fe/mL,94.6%(35/37)患者平均浓度低于1.0 mg Fe/mL;36/37例患者存在区域高浓度,主要位于肝中上部(75%)、内侧(72.2%)和前部(83.3%)。结论认为双源双能量CT可用于评估健康受试者肝铁分布均匀性。

要点

  • 健康肝脏铁浓度并非均匀分布,36/37例存在区域高浓度。
  • 区域高浓度主要位于肝中上部(75%)、内侧(72.2%)、前部(83.3%)。
  • 94.6%(35/37)肝功能正常者全肝平均铁浓度低于1.0 mg Fe/mL。

核心结论

  • 双源双能量CT可用于评估健康受试者肝铁分布的均匀性。
  • 健康肝脏铁浓度不均匀,多数存在区域高浓度,好发于肝中上部、内侧和前部。

研究设计与样本

  • 体模研究:用硝酸铁溶液与去离子水配制10种混合物,置试管内以双源双能量128层CT系统扫描,经三物质分解算法生成铁图像,计算转换因子。
  • 回顾性分析因肾结石行双源双能量CT检查的患者,随机选取37例肝功能正常者,平均年龄52.5岁。
  • 对检查图像进行铁浓度处理,分析多个感兴趣区,报告铁浓度(mg Fe/mL)及分布。

关键影像表现/征象

  • 全肝平均铁浓度范围为0.0至2.91 mg Fe/mL。
  • 94.6%(35/37)的患者全肝平均铁浓度低于1.0 mg Fe/mL。
  • 36/37例患者存在区域高浓度,高浓度区主要位于肝中上部(75%)、内侧(72.2%)和前部(83.3%)。

诊断标准与关键数值

  • 体模研究得出的平均转换因子为0.15 mg Fe/mL每Hounsfield单位。
  • 全肝平均铁浓度正常范围为0.0至2.91 mg Fe/mL(基于37例肝功能正常者)。

临床应用与阅片要点

  • 阅片时应注意健康肝脏铁浓度存在区域差异,肝中上部、内侧和前部可能出现区域高浓度。
  • 报告肝铁浓度时应考虑全肝平均浓度与区域高浓度的差异,避免将正常区域高浓度误判为异常。
  • 作者指出未来研究可将该技术应用于不健康肝脏,关注肝铁含量及分布对病变受试者无创评估的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers.

MATERIALS AND METHODS: Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported.

RESULTS: The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%).

CONCLUSIONS: Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Abadia AF, Grant KL, Carey KE, et al. Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging. Invest Radiol. 2017. PMID: 28562414. doi:10.1097/RLI.0000000000000393

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。