基于CT的影像组学标签用于鉴别Borrmann IV型胃癌与原发性胃淋巴瘤
回顾性纳入40例Borrmann IV型胃癌和30例原发性胃淋巴瘤患者,从门静脉期CT提取并筛选485个影像组学特征构建标签,并与主观CT征象模型及联合模型比较诊断效能。三种模型AUC无显著差异(P=0.051-0.422),影像组学分析有潜力准确鉴别Borrmann IV型胃癌与原发性胃淋巴瘤。
要点
- 联合模型特异度达100%,影像组学标签敏感度86.67%,主观征象模型特异度95.00%。
- 三种模型AUC分别为0.806、0.886、0.903,两两比较无显著差异(P=0.051-0.422)。
- 主观CT征象包括胃壁蠕动、胃周脂肪浸润、肾门以下淋巴结增大及强化方式。
核心结论
- 影像组学分析有潜力准确鉴别Borrmann IV型胃癌与原发性胃淋巴瘤。
研究设计与样本
- 回顾性纳入40例Borrmann IV型胃癌和30例原发性胃淋巴瘤患者,从门静脉期CT图像提取并筛选485个影像组学特征构建标签,以主观CT征象构建主观征象模型,并将影像组学标签、主观CT征象、年龄和性别经多因素分析整合为联合模型,采用ROC曲线和DeLong检验比较三种模型诊断效能。
关键影像表现/征象
- 主观CT征象评估包括胃壁蠕动、胃周脂肪浸润、肾门以下淋巴结增大和强化方式。
诊断标准与关键数值
- 主观征象模型诊断准确率81.43%,AUC 0.806(95%CI 0.696-0.917),敏感度63.33%,特异度95.00%。
- 影像组学标签诊断准确率84.29%,AUC 0.886(95%CI 0.809-0.963),敏感度86.67%,特异度82.50%。
- 联合模型诊断准确率87.14%,AUC 0.903(95%CI 0.831-0.975),敏感度70.00%,特异度100%。
- 三种模型AUC两两比较无显著差异(P=0.051-0.422)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the value of CT-based radiomics signature for differentiating Borrmann type IV gastric cancer (GC) from primary gastric lymphoma (PGL).
MATERIALS AND METHODS: 40 patients with Borrmann type IV GC and 30 patients with PGL were retrospectively recruited. 485 radiomics features were extracted and selected from the portal venous CT images to build a radiomics signature. Subjective CT findings, including gastric wall peristalsis, perigastric fat infiltration, lymphadenopathy below the renal hila and enhancement pattern, were assessed to construct a subjective findings model. The radiomics signature, subjective CT findings, age and gender were integrated into a combined model by multivariate analysis. The diagnostic performance of these three models was assessed with receiver operating characteristics curves (ROC) and were compared using DeLong test.
RESULTS: The subjective findings model, the radiomics signature and the combined model showed a diagnostic accuracy of 81.43% (AUC [area under the curve], 0.806; 95% CI [confidence interval]: 0.696-0.917; sensitivity, 63.33%; specificity, 95.00%), 84.29% (AUC, 0.886 [95% CI: 0.809-0.963]; sensitivity, 86.67%; specificity, 82.50%), 87.14% (AUC, 0.903 [95%CI: 0.831-0.975]; sensitivity, 70.00%; specificity, 100%), respectively. There were no significant differences in AUC among these three models (P=0.051-0.422).
CONCLUSION: Radiomics analysis has the potential to accurately differentiate Borrmann type IV GC from PGL.
引用
- Ma Z, Fang M, Huang Y, et al. CT-based radiomics signature for differentiating Borrmann type IV gastric cancer from primary gastric lymphoma. Eur J Radiol. 2017. PMID: 28629560. doi:10.1016/j.ejrad.2017.04.007