CT检查中碘对比剂增强辐射所致DNA损伤
研究纳入70例患者,比较CT尿路造影(注射碘对比剂后单次CT扫描)与平扫全腹部CT对外周血淋巴细胞DNA双链断裂(γH2AX焦点)的影响,发现CTU组焦点数高于平扫组约37.9%,且CT前注射碘对比剂本身可使焦点数增加约90.3%,而照射后注射则无显著差异。
要点
- CT尿路造影组γH2AX焦点数0.945±0.184个/细胞,高于平扫全腹部CT组的0.700±0.112个/细胞,增加约37.9%。
- CT前注射碘对比剂使γH2AX焦点数增加约90.3%(0.059±0.018 vs 0.031±0.025,P<0.05)。
- 照射后注射碘对比剂仅使焦点数增加约3.2%(0.711±0.091 vs 0.689±0.108,P=0.499),无显著差异。
核心结论
- 碘对比剂本身可导致γH2AX焦点形成所评估的DNA双链断裂水平升高,且应用碘对比剂可放大全腹部CT等诊断性X线检查所致的DNA损伤。
研究设计与样本
- 经机构伦理委员会批准的前瞻性研究,纳入70例患者,其中48例接受CT尿路造影(注射碘对比剂后仅进行一次CT扫描),22例接受平扫全腹部CT(其中10例在照射后立即注射碘对比剂);所有患者于CT扫描前、扫描后立即及注射碘对比剂后8分钟采集血样,经密度梯度离心分离淋巴细胞、固定并以γH2AX抗体免疫染色,荧光显微镜下计数每个淋巴细胞的γH2AX焦点平均数,采用独立样本t检验和单因素方差分析进行统计。
诊断标准与关键数值
- 以每个淋巴细胞的磷酸化组蛋白H2AX(γH2AX)焦点平均数作为DNA双链断裂的评估指标。
- CT尿路造影组γH2AX焦点数为0.945±0.184个/细胞(均值±标准误),平扫全腹部CT组为0.700±0.112个/细胞(均值±标准误),CTU组较平扫组增加约37.9%。
- CT前注射碘对比剂使γH2AX焦点数增加约90.3%(0.059±0.018 vs 0.031±0.025,P<0.05)。
- 照射后注射碘对比剂使γH2AX焦点数增加约3.2%(0.711±0.091 vs 0.689±0.108,P=0.499),无显著差异。
- 三组患者基线焦点数无显著差异(P>0.05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To access the effect of iodinate contrast agent (ICA) on DNA double-stand breaks (DSBs) in human peripheral blood lymphocytes during computed tomography (CT) examinations.
MATERIALS AND METHODS: This present study was approved by the institutional ethics committee; written informed patient consent was obtained from 70 patients. A total of 48 patients underwent computed tomography urography (CTU), in which only one time CT scanning was examined after injecting ICA, and 22 patients received unenhanced whole abdominal CT, among them 10 patients were selected to get ICA injection immediately after irradiation. Blood samples were taken from all patients prior to and immediately after CT scan, as well as 8min after the injection of ICA. The lymphocytes in these blood samples were separated by using density-gradient centrifugation, fixed and immunostained with γH2AX antibody. The average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was counted under a fluorescence microscopy. Differences in the number of γH2AX-foci were statistically analyzed using independent sample t test and one way ANOVA.
RESULT: The three patient groups had no significant differences in the baseline foci numbers(P>0.05). The γH2AX-focus levels increased in both groups after CT scan. Patients who underwent CTU examinations had a greater DSBs level (mean±standard error of mean, 0.945±0.184 foci per cell) than those who received unenhanced whole abdominal CT scan (mean±standard error of mean, 0.700±0.112 foci per cell), increasing by about 37.9%; The ICA injected before CT scan itself had an effect on the DSBs, which increased DSBs level by approximately 90.3% (0.059±0.018vs 0.031±0.025, P<0.05), but no significant difference was found if added after irradiation, increasing DSBs level only by 3.2% approximately (0.711±0.091vs 0.689±0.108, P=0.499).
CONCLUSION: The iodinated contrast agent itself can lead to an increase in the level of DSBs as assessed with γH2AX foci formation, and the application of ICA can amplify DNA damage induced by diagnostic x-ray procedures such as whole abdominal CT.
引用
- Wang L, Li Q, Wang XM, et al. Enhanced radiation damage caused by iodinated contrast agents during CT examination. Eur J Radiol. 2017. PMID: 28624023. doi:10.1016/j.ejrad.2017.04.005