通过减少z轴覆盖范围在320排冠状动脉CT血管成像中降低辐射剂量的量化研究
回顾性分析130例320排CT冠状动脉CTA,测量心脏头尾方向尺寸并计算将z轴覆盖缩减至刚好覆盖心脏时可节省的剂量。平均DLP为417.6±182.4 mGy cm,可节省96.2±47.4 mGy cm,平均降低26.9±7.0%。z轴覆盖≤12 cm对92%受检者足够,12.8 cm对98%足够,14 cm对100%足够。
要点
- 使用刚好覆盖心脏的最小z轴覆盖是降低320排CCTA剂量的简单步骤,平均可降低DLP约27%。
- z轴覆盖≤12 cm对92%受检者足够,12.8 cm对98%足够,14 cm对100%足够。
- 本组85%(112/130)的CCTA采用了16 cm的z轴覆盖。
核心结论
- 使用刚好覆盖心脏的最小z轴覆盖是降低320排CCTA辐射剂量的简单步骤,平均可降低DLP约27%。
研究设计与样本
- 回顾性分析130例在320排CT(z轴覆盖最大16 cm,可按2 cm增量调节,单圈旋转可完整覆盖心脏)上进行的冠状动脉CTA,测量辐射剂量(CT剂量指数和DLP)、z轴视野及心脏头尾方向尺寸(左主干冠状动脉至心尖的距离)。
关键影像表现/征象
- 平均心脏头尾方向尺寸为10.5±1.0 cm。
- 85%(n=112)的CCTA采用16 cm的z轴覆盖。
诊断标准与关键数值
- 平均DLP为417.6±182.4 mGy cm。
- 使用刚好覆盖心脏的最小z轴覆盖可节省的平均DLP为96.2±47.4 mGy cm,平均剂量降低26.9±7.0%。
- z轴覆盖≤12 cm对92%受检者足够,12.8 cm对98%受检者足够,14 cm对100%受检者足够。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To quantify the radiation dose reduction achievable by minimizing z-axis coverage in 320-detector coronary CT angiography (CCTA).
METHODS: We retrospectively reviewed 130 CCTAs performed on 320-detector CT that offers up to 16 cm z-axis coverage (adjustable in 2-cm increments), allowing complete coverage of the heart in a single gantry rotation. For each CT, we obtained the radiation dose [CT dose index and dose-length product (DLP)], measured the z-axis field of view and measured the craniocaudal cardiac size (distance from the left main coronary artery to the cardiac apex). We calculated the radiation dose savings achievable by reducing the z-axis coverage to the minimum necessary to cover the heart using 320 × 0.5-mm (maximum 16 cm) and 256 × 0.5-mm (maximum 12.8 cm) detector collimations.
RESULTS: Results are expressed as mean ± standard deviation. The mean craniocaudal cardiac size was 10.5 ± 1.0 cm, with 85% (n = 112) of CCTAs performed with 16 cm of z-axis coverage. The mean DLP was 417.6 ± 182.4 mGy cm, with the mean DLP saving achievable using the minimum z-axis coverage required to completely image the heart being 96.2 ± 47.4 mGy cm, an average dose reduction of 26.9 ± 7.0%. z-axis coverage of ≤12 cm was adequate for 92% and 12.8 cm for 98% of subjects.
CONCLUSION: Using the minimal z-axis coverage to adequately image the heart is a simple step that can reduce the DLP in 320-detector CCTA by approximately 27%. z-axis coverage of ≤12 cm is adequate for 92%, 12.8 cm for 98% and 14 cm for 100% of patients undergoing CCTA. Advances in knowledge: Reducing z-axis coverage in 320-detector CCTA can reduce DLP by approximately 27%.
引用
- Murphy DJ, Keraliya A, Himes N, et al. Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography. Br J Radiol. 2017. PMID: 28613933. doi:10.1259/bjr.20170252
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。