特征追踪心血管磁共振检测梗死节段的诊断能力:与标记磁共振及室壁增厚分析的比较
回顾性纳入20例确诊心肌梗死患者,基于16节段模型量化心内膜环周应变峰值,比较特征追踪心血管磁共振、标记磁共振及室壁增厚分析检测梗死节段的诊断能力。共分析320个节段,特征追踪磁共振诊断效能优于室壁增厚分析,且能区分心内膜下梗死与透壁性梗死,而标记磁共振需额外采集序列。
要点
- 特征追踪磁共振诊断梗死节段的AUC为0.77,优于室壁增厚分析的0.64。
- 透壁性梗死的环周应变峰值显著低于心内膜下梗死(p<0.05)及无梗死节段(p<0.001)。
- 特征追踪磁共振无需额外采集序列,即可区分心内膜下与透壁性梗死。
核心结论
- 特征追踪心血管磁共振诊断效能优于室壁增厚分析,且能区分心内膜下梗死与透壁性梗死;与标记磁共振不同,特征追踪磁共振无需额外采集序列。
研究设计与样本
- 回顾性研究,纳入20例确诊心肌梗死患者,基于16节段模型量化心内膜环周应变峰值,以延迟钆增强磁共振为参考标准将节段分类为透壁性梗死、心内膜下梗死和无梗死。
关键影像表现/征象
- 透壁性梗死的环周应变峰值显著低于心内膜下梗死(p<0.05)和无梗死节段(p<0.001)。
诊断标准与关键数值
- 特征追踪磁共振环周应变截断值-11.2%鉴别梗死与非梗死节段,敏感度72%、特异度71%、准确率72%、阳性预测值57%、阴性预测值83%、AUC 0.77。
- 标记磁共振环周应变截断值-10.9%鉴别梗死与非梗死节段,敏感度71%、特异度75%、准确率73%、阳性预测值60%、阴性预测值83%、AUC 0.79。
- 室壁增厚率截断值23.8%鉴别梗死与非梗死节段,敏感度56%、特异度67%、准确率63%、阳性预测值48%、阴性预测值74%、AUC 0.64。
临床应用与阅片要点
- 特征追踪磁共振可在不额外采集序列的情况下评估节段性功能异常,辅助鉴别梗死与非梗死节段。
- 透壁性梗死的环周应变峰值较心内膜下梗死更低,可用于区分梗死透壁程度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To examine the diagnostic capabilities of feature-tracking cardiovascular magnetic resonance (FT-CMR), tagged cine magnetic resonance (MR), and wall thickening (WT) analyses to detect infarcted segments in patients with established myocardial infarction (MI).
MATERIALS AND METHODS: Twenty patients with established MI were selected retrospectively and the peak endocardial circumferential strain (CS) was quantified based on the 16-segment model. According to CMR with late gadolinium enhancement, segments were categorised as transmural MI, subendocardial MI, and no MI.
RESULTS: A total of 320 segments (62 transmural MI, 50 subendocardial MI, and 208 no MI) were analysed. Peak endocardial CS was significantly lower for transmural MI compared with subendocardial MI (p<0.05) and no MI (p<0.001). Cut-off values of -11.2% for CS by FTCMR, -10.9% for CS by tagged MR, and 23.8% for %WT, differentiated between infarcted and non-infarcted segments with a sensitivity of 72%, 71%, and 56%; specificity of 71%, 75%, and 67%; accuracy of 72%, 73%, and 63%; positive predictive value of 57%, 60%, and 48%; negative predictive value of 83%, 83%, and 74%; and an area-under-the-curve of 0.77, 0.79, and 0.64, respectively.
CONCLUSIONS: FT-CMR was diagnostically superior to %WT, and could differentiate between subendocardial and transmural MI. Unlike tagged MR, FT-CMR did not require the acquisition of additional sequences.
引用
- Ogawa R, Kido T, Nakamura M, et al. Diagnostic capability of feature-tracking cardiovascular magnetic resonance to detect infarcted segments: a comparison with tagged magnetic resonance and wall thickening analysis. Clin Radiol. 2017. PMID: 28615141. doi:10.1016/j.crad.2017.05.010