文献速递外周血管腹部MRCT

三维平衡稳态自由进动非增强MR血管成像评估腹腔干和肠系膜上动脉狭窄:与CT血管成像的初步对比研究

Non-contrast MR angiography using three-dimensional balanced steady-state free-precession imaging for evaluation of stenosis in the celiac trunk and superior mesenteric artery: a preliminary comparative study with computed tomography angiography.
PubMed 文献 · Br J Radiol · 2017-06-07

本研究对41例患者行腹腔干和肠系膜上动脉的非增强MR血管成像(三维平衡稳态自由进动序列)与CT血管成像对比,评估图像质量和诊断狭窄的准确性。非增强MR血管成像对腹腔干和肠系膜上动脉狭窄的敏感度均为100%,准确率分别为88.8%和94.5%,提示其可作为对比剂禁忌患者的非增强替代方法。

要点

  • 非增强MR血管成像对腹腔干和肠系膜上动脉狭窄的敏感度均为100%,阴性预测值均为100%。
  • 非增强MR血管成像诊断腹腔干和肠系膜上动脉狭窄的准确率分别为88.8%和94.5%。
  • 腹腔干和肠系膜上动脉的诊断质量图像比例分别为87.8%和90.2%。

核心结论

  • 非增强MR血管成像(三维平衡稳态自由进动序列)是检测腹腔干和肠系膜上动脉狭窄的准确方法。

研究设计与样本

  • 初步对比研究,41例患者均行腹主动脉非增强MR血管成像和CT血管成像,以CT血管成像为参考标准,由两名放射科医生分析图像质量和狭窄诊断效能。

诊断标准与关键数值

  • 非增强MR血管成像对腹腔干和肠系膜上动脉狭窄的敏感度均为100%,阳性预测值均为50%,阴性预测值均为100%,准确率腹腔干为88.8%、肠系膜上动脉为94.5%。

临床应用与阅片要点

  • 原文结论提示,对于存在对比剂增强检查禁忌证的患者,三维平衡稳态自由进动序列MR血管成像可作为评估腹腔干和肠系膜上动脉狭窄的非增强替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Although non-contrast MR angiography (NC-MRA) is well established for the evaluation of renal artery stenosis, its usefulness in the evaluation of other abdominal aortic branches remains to be studied. This study aimed at evaluating the image quality and diagnostic accuracy of NC-MRA using a three-dimensional balanced steady-state free-precession sequence in identifying stenosis in the celiac trunk (CTR) and superior mesenteric artery (SMA) as compared with CT angiography (CTA) as the reference standard.

METHODS: 41 patients underwent both NC-MRA and CTA of the abdominal aorta. Two radiologists analyzed the quality of the images (diagnostic vs non-diagnostic) and the performance (accuracy, sensitivity and specificity) of NC-MRA for the identification of arterial stenosis. Kappa tests were used to determine the interobserver agreement and the intermethod agreement between NC-MRA and CTA.

RESULTS: NC-MRA provided diagnostic quality images of the CTR and SMA in 87.8% and 90.2% of cases, respectively, with high interobserver agreement (kappa 0.95 and 0.80, respectively). For stenosis assessment, NC-MRA had a sensitivity of 100%, a positive-predictive value of 50% and a negative-predictive value of 100% for both segments, with accuracies of 88.8% for the CTR and 94.5% for the SMA.

CONCLUSION: NC-MRA is an accurate method for detecting stenosis in the CTR and SMA. Advances in knowledge: Data from this study suggest that MR angiography with balanced steady-state free-precession sequence is a viable non-contrast alternative for stenosis evaluation of these branches in patients for whom a contrast-enhanced examination is contraindicated.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Cardia PP, Penachim TJ, Prando A, et al. Non-contrast MR angiography using three-dimensional balanced steady-state free-precession imaging for evaluation of stenosis in the celiac trunk and superior mesenteric artery: a preliminary comparative study with computed tomography angiography. Br J Radiol. 2017. PMID: 28590771. doi:10.1259/bjr.20170011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。