文献速递心血管MR

基于T2-mapping分析组织不均匀性定量检测急性心肌炎心肌水肿的新方法再评价

Re-evaluation of a novel approach for quantitative myocardial oedema detection by analysing tissue inhomogeneity in acute myocarditis using T2-mapping.
PubMed 文献 · Eur Radiol · 2017-06-27

含像素标准差参数的模型均优于含整体心肌T2的模型;madSD 1.8 ms联合maxT2 68 ms的诊断敏感度75%、特异度80%,与Lake Louise标准(LLC)诊断性能相似;madSD、maxT2联合晚期钆增强(LGE)的模型敏感度93%、特异度83%,优于LLC。

要点

  • T2-mapping衍生的maxT2与madSD联合阈值(madSD 1.8 ms+maxT2 68 ms)诊断性能与LLC相似。
  • madSD、maxT2联合LGE的模型敏感度93%、特异度83%,优于LLC。
  • 含像素标准差参数的模型均优于含整体心肌T2的模型。

核心结论

  • T2-mapping衍生的新参数在LGE基础上具有附加诊断价值,并具有克服当前T2-mapping局限性的内在潜力。

关键影像表现/征象

  • 分析节段T2值、节段像素标准差(SD)及衍生参数maxT2、maxSD和madSD。
  • 含SD参数的模型均优于含整体心肌T2的模型。
  • madSD 1.8 ms联合maxT2 68 ms的诊断敏感度75%、特异度80%,与LLC诊断性能相似。
  • madSD、maxT2联合LGE的模型敏感度93%、特异度83%,优于LLC。

诊断标准与关键数值

  • madSD阈值1.8 ms联合maxT2阈值68 ms:诊断敏感度75%、特异度80%。
  • madSD、maxT2联合LGE模型:诊断敏感度93%、特异度83%。
  • 对照标准为Lake Louise标准(LLC)。

临床应用与阅片要点

  • 原文结论认为T2-mapping衍生参数在LGE基础上具有附加诊断价值,并可能克服当前T2-mapping的局限性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To re-evaluate a recently suggested approach of quantifying myocardial oedema and increased tissue inhomogeneity in myocarditis by T2-mapping.

METHODS: Cardiac magnetic resonance data of 99 patients with myocarditis were retrospectively analysed. Thirthy healthy volunteers served as controls. T2-mapping data were acquired at 1.5 T using a gradient-spin-echo T2-mapping sequence. T2-maps were segmented according to the 16-segments AHA-model. Segmental T2-values, segmental pixel-standard deviation (SD) and the derived parameters maxT2, maxSD and madSD were analysed and compared to the established Lake Louise criteria (LLC).

RESULTS: A re-estimation of logistic regression models revealed that all models containing an SD-parameter were superior to any model containing global myocardial T2. Using a combined cut-off of 1.8 ms for madSD + 68 ms for maxT2 resulted in a diagnostic sensitivity of 75% and specificity of 80% and showed a similar diagnostic performance compared to LLC in receiver-operating-curve analyses. Combining madSD, maxT2 and late gadolinium enhancement (LGE) in a model resulted in a superior diagnostic performance compared to LLC (sensitivity 93%, specificity 83%).

CONCLUSIONS: The results show that the novel T2-mapping-derived parameters exhibit an additional diagnostic value over LGE with the inherent potential to overcome the current limitations of T2-mapping.

KEY POINTS: • A novel quantitative approach to myocardial oedema imaging in myocarditis was re-evaluated. • The T2-mapping-derived parameters maxT2 and madSD were compared to traditional Lake-Louise criteria. • Using maxT2 and madSD with dedicated cut-offs performs similarly to Lake-Louise criteria. • Adding maxT2 and madSD to LGE results in further increased diagnostic performance. • This novel approach has the potential to overcome the limitations of T2-mapping.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Baeßler B, Schaarschmidt F, Treutlein M, et al. Re-evaluation of a novel approach for quantitative myocardial oedema detection by analysing tissue inhomogeneity in acute myocarditis using T2-mapping. Eur Radiol. 2017. PMID: 28656464. doi:10.1007/s00330-017-4894-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。