PET重建技术与矩阵大小对[18F]-FDG-PET肺部病灶定性和定量评估的影响:一项37例癌症患者的前瞻性研究
前瞻性纳入37例肿瘤患者共206个肺病灶,比较基于点扩散函数的TrueX与2D OSEM两种重建算法及168×168与336×336两种矩阵对PET肺病灶检出和SUV的影响。TrueX检出敏感度显著高于OSEM,336×336矩阵SUVmax和SUVmean显著高于168×168矩阵。
要点
- TrueX重建对代谢活跃肺病灶的检出敏感度高于OSEM重建。
- 336×336矩阵较168×168矩阵的SUVmax和SUVmean显著升高。
- 不同重建算法和矩阵的PET数据跨机构比较时SUV差异需注意。
核心结论
- 基于点扩散函数的PET重建可提高代谢活跃肺病灶的检出,增大矩阵也有较小程度的改善,但两者均导致SUV升高,跨机构比较PET数据时可能存在问题。
研究设计与样本
- 前瞻性研究,纳入37例接受[18F]-FDG-PET/CT分期的肿瘤患者,共206个肺病灶;PET数据分别用2D OSEM算法和2D TrueX(基于点扩散函数)算法重建,各采用168×168和336×336两种矩阵,共4种重建图像;两位阅片者独立判读PET阳性肺病灶,第三位独立阅片者在不知PET结果情况下评估CT上直径>4mm的肺病灶,随后PET与CT共识侧边对照复习;采用多因素logistic回归和双因素重复测量方差分析。
诊断标准与关键数值
- 病灶水平PET敏感度:阅片者1和阅片者2分别为TrueX-336 94.2%和88.3%、TrueX-168 88.3%和85.9%、OSEM-336 67.8%和66.3%、OSEM-168 67.0%和67.9%。
- 不同重建算法间病灶水平PET敏感度差异显著(P<0.001),不同重建矩阵间差异显著(P=0.022)。
- 336×336矩阵重建图像的SUVmax和SUVmean显著高于168×168矩阵重建图像(P<0.001)。
局限性
- 基于点扩散函数的PET重建和较大矩阵导致SUV升高,原文指出当比较不同机构的PET数据时这可能是一个问题。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the influence of point spread function (PSF)-based reconstruction and matrix size for PET on (1) lung lesion detection and (2) standardized uptake values (SUV).
METHODS: This prospective study included oncological patients who underwent [18F]-FDG-PET/CT for staging. PET data were reconstructed with a 2D ordered subset expectation maximization (OSEM) algorithm, and a 2D PSF-based algorithm (TrueX), separately with two matrix sizes (168×168 and 336×336). The four PET reconstructions (TrueX-168; OSEM-168; TrueX-336; and OSEM-336) were read independently by two raters, and PET-positive lung lesions were recorded. Blinded to the PET findings, a third independent rater assessed lung lesions with diameters of >4mm on CT. Subsequently, PET and CT were reviewed side-by side in consensus. Multi-factorial logistic regression analyses and two-way repeated measures analyses of variance (ANOVA) were performed.
RESULTS: Thirty-seven patients with 206 lung lesions were included. Lesion-based PET sensitivities differed significantly between reconstruction algorithms (P<0.001) and between reconstruction matrices (P=0.022). Sensitivities were 94.2% and 88.3% for TrueX-336; 88.3% and 85.9% for TrueX-168; 67.8% and 66.3% for OSEM-336; and 67.0% and 67.9% for OSEM-168; for rater 1 and rater 2, respectively. SUVmax and SUVmean were significantly higher for images reconstructed with 336×336 matrices than for those reconstructed with 168×168 matrices (P<0.001).
CONCLUSION: Our results demonstrate that PSF-based PET reconstruction, and, to a lesser degree, higher matrix size, improve detection of metabolically active lung lesions. However, PSF-based PET reconstructions and larger matrix sizes lead to higher SUVs, which may be a concern when PET data from different institutions are compared.
引用
- Riegler G, Karanikas G, Rausch I, et al. Influence of PET reconstruction technique and matrix size on qualitative and quantitative assessment of lung lesions on [18F]-FDG-PET: A prospective study in 37 cancer patients. Eur J Radiol. 2017. PMID: 28583635. doi:10.1016/j.ejrad.2017.02.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。