总肺容量、性别与身高对CT气道测量的影响
这项经伦理委员会批准的前瞻性研究纳入87名健康从不吸烟志愿者,于胸部螺旋CT上由三名读者两次测量第三、四级气道壁厚度与管腔面积,并计算WA%与√WAPi10、以CT测量总肺容量(TLCCT)。结果显示√WAPi10、WT3rd与WT4th存在性别差异;两性中气道测量与TLCCT均无显著相关;仅女性中WT3rd和WT4th与身高呈显著负相关。作者认为CT气道测量受性别影响、女性中受身高影响,应按性别及女性身高进行调整。
要点
- √WAPi10、第三级气道壁厚度(WT3rd)与第四级气道壁厚度(WT4th)在男女间存在显著差异。
- 无论男女,各项气道测量与CT测得的总肺容量(TLCCT)均无显著相关。
- 仅女性中WT3rd和WT4th与身高呈显著负相关,男性中未见此相关。
核心结论
- √WAPi10、WT3rd与WT4th在男性与女性间存在差异,WT3rd与WT4th仅在女性中与身高相关、与TLC无关,男性中与身高亦无相关。
- 作者认为CT气道测量受性别影响、女性中受身高影响,应按性别和女性身高进行调整。
研究设计与样本
- 经伦理委员会批准的前瞻性研究,纳入87名提供书面知情同意书的健康从不吸烟志愿者。
- 基于胸部螺旋CT,由三名读者使用专用软件对第三、四级气道各测量两次壁厚度(WT)与管腔面积。
- 同时以CT测量总肺容量(TLCCT),并计算气道壁占气道面积的百分比(WA%)及内周长为10 mm时壁面积的平方根(√WAPi10)。
- 采用混合线性模型比较男女间CT气道测量,采用Pearson相关分析检验身高、TLCCT与CT气道测量的相关性,六个测量时段均观察到显著相关才判定为显著。
诊断标准与关键数值
- 男女间√WAPi10、WT3rd与WT4th存在显著差异。
- 两性中各项气道测量与TLCCT均无显著相关。
- 仅女性中WT3rd与WT4th与身高呈显著负相关。
临床应用与阅片要点
- 作者认为CT气道测量应按性别调整,女性还应按身高调整。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Testing the hypothesis that CT airway measurements could be influenced by total lung capacity (TLC), gender and height in normal individuals.
METHODS: In this ethics committee-approved prospective trial, 87 healthy never-smoking volunteers who provided written informed consent were included. From a helical CT scan of the chest, the wall thickness (WT) and the lumen area were twice measured in the third- and fourth-generation airways by three readers using a dedicated software. In addition, the TLC was also measured using CT (TLCCT). The percentage of airway area occupied by the wall (WA%) and the square root of wall area at an internal perimeter of 10 mm (√WAPi10) were calculated. CT airway measurements were compared between genders by using a mixed linear model. The correlations between height, TLCCT and CT airway measurements were tested by using a Pearson correlation analysis. These correlations were arbitrarily considered as significant if there was a significant correlation observed for each of the six measurement sessions.
RESULTS: √WAPi10, WT3rd and WT4th were significantly different between genders. For both genders, there was no significant correlation between any airway measurements and TLCCT. In females only, WT3rd and WT4th were significantly and negatively correlated with height.
CONCLUSION: √WAPi10, WT3rd and WT4th are different in males and females. WT3rd and WT4th are correlated with height in females only but not with TLC or in males. Advances in knowledge: CT airway measurements are influenced by gender and by height in females only but not by TLC. They should be adjusted according to gender and height in females.
引用
- Hackx M, Francotte D, Garcia TS, et al. Effect of total lung capacity, gender and height on CT airway measurements. Br J Radiol. 2017. PMID: 28613927. doi:10.1259/bjr.20160898
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。