文献速递神经头颈MR

冠状位高分辨率扩散加权成像在急性视神经炎中的作用:与轴位方向的比较

Role of coronal high-resolution diffusion-weighted imaging in acute optic neuritis: a comparison with axial orientation.
PubMed 文献 · Neuroradiology · 2017-06-24

本研究对49例急性视力丧失患者行眶区RESOLVE-DWI,比较冠状位(层厚3 mm)与轴位(层厚2 mm)对急性视神经炎的诊断准确性和ADC测量可重复性。冠状位RESOLVE-DWI的敏感度、特异度、准确度分别为85.1/87.2%、90.2/94.12%、87.8/90.8%,轴位分别为83.0/85.1%、66.7/76.5%、75.5/79.6%;冠状位特异度更高、ADC测量可重复性更好。

要点

  • 冠状位RESOLVE-DWI诊断急性视神经炎的特异度(90.2/94.12%)高于轴位(66.7/76.5%)。
  • 冠状位RESOLVE-DWI的ADC测量观察者间ICC为0.941,CV为4.810%,可重复性优于轴位(ICC 0.846,CV 7.046%)。
  • 临床阳性视神经ADC值显著低于阴性组(P < 0.0001)。

核心结论

  • 冠状位RESOLVE-DWI具有更高的特异度和更好的ADC测量可重复性,证明其用于检查急性视神经炎患者的可行性。

研究设计与样本

  • 回顾性研究,纳入49例急性视力丧失患者,采用基于读出分段、并行成像和2D导航者重采集的RESOLVE-DWI行眶区DWI,冠状位层厚3 mm、轴位层厚2 mm,由两名神经放射科医生评估,以临床诊断为标准计算诊断试验指标。

关键影像表现/征象

  • 临床阳性视神经ADC值显著低于临床阴性视神经(P < 0.0001)。
  • Bland-Altman图显示冠状位RESOLVE-DWI的观察者间变异性更小。

诊断标准与关键数值

  • 冠状位RESOLVE-DWI诊断急性视神经炎的敏感度85.1/87.2%、特异度90.2/94.12%、准确度87.8/90.8%。
  • 轴位RESOLVE-DWI诊断急性视神经炎的敏感度83.0/85.1%、特异度66.7/76.5%、准确度75.5/79.6%。
  • 冠状位RESOLVE-DWI观察者间kappa值0.806、观察者内kappa值0.909;轴位分别为0.710和0.822(各P < 0.0001)。
  • 冠状位RESOLVE-DWI观察者间ADC测量ICC 0.941、CV 4.810%;轴位分别为0.846和7.046%。

临床应用与阅片要点

  • 冠状位RESOLVE-DWI可用于检查急性视神经炎患者,其特异度和ADC测量可重复性优于轴位。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Through a comparison with the axial orientation, we aimed to evaluate the role of coronal high-resolution diffusion-weighted imaging (DWI) in acute optic neuritis based on diagnostic accuracy and the reproducibility of apparent diffusion coefficient (ADC) measurements.

METHODS: Orbital DWI, using readout-segmented, parallel imaging, and 2D navigator-based reacquisition (RESOLVE-DWI), was performed on 49 patients with acute vision loss. The coronal (thickness = 3 mm) and axial (thickness = 2 mm) diffusion images were evaluated by two neuroradiologists retrospectively. The sensitivity, specificity, and accuracy were calculated through diagnostic test; the inter- and intra-observer reliabilities were assessed with a weighted Cohen's kappa test. In addition, the agreement of ADC measurement among observers was evaluated by the intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman plots. Comparison of ADC values was also performed by unpaired t test.

RESULTS: Among the 49 patients, 47 clinically positive optic nerves and 51 clinically negative optic nerves were found. The sensitivity, specificity, and accuracy were 85.1/87.2%, 90.2/94.12%, and 87.8/90.8%, respectively, for coronal RESOLVE-DWI and 83.0/85.1%, 66.7/76.5%, and 75.5/79.6%, respectively, for axial RESOLVE-DWI. The inter-observer kappa values were 0.710 and 0.806 for axial and coronal RESOLVE-DWI, respectively, and the intra-observer kappa values were 0.822 and 0.909, respectively (each P < 0.0001). Regarding the reproducibility of ADC measurements on axial and coronal RESOLVE-DWI, the ICCs among observers were 0.846 and 0.941, respectively, and the CV values were 7.046 and 4.810%, respectively. Bland-Altman plots revealed smaller inter-observer variability on coronal RESOLVE-DWI. ADC values were significantly lower in positive group (each P < 0.0001).

CONCLUSION: Higher specificity and better reproducibility of ADC measurements were found for coronal RESOLVE-DWI, which demonstrated the feasibility of the use of coronal RESOLVE-DWI to examine acute optic neuritis patients.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Lu P, Sha Y, Wan H, et al. Role of coronal high-resolution diffusion-weighted imaging in acute optic neuritis: a comparison with axial orientation. Neuroradiology. 2017. PMID: 28647756. doi:10.1007/s00234-017-1853-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。