文献速递头颈技术与安全MR

头颈部鳞状细胞癌淋巴结转移:体素内不相干运动磁共振成像鉴别诊断的效能

Lymph node metastasis in head and neck squamous carcinoma: Efficacy of intravoxel incoherent motion magnetic resonance imaging for the differential diagnosis.
PubMed 文献 · Eur J Radiol · 2017-03-02

回顾性纳入29例头颈部鳞状细胞癌患者和20例淋巴结增生患者,比较恶性与良性淋巴结的IVIM参数D、D*、f及ADC值,恶性淋巴结ADC、D、f显著降低而D*显著升高,D·D*的AUC为0.983,高于D*(0.952)、D(0.78)和ADC(0.67)。

要点

  • 恶性淋巴结D、f、ADC值显著低于良性淋巴结,D*显著高于良性淋巴结。
  • D·D*的AUC为0.983,高于D*的0.952、D的0.78和ADC的0.67。
  • IVIM-DWI可用于头颈部鳞状细胞癌淋巴结转移的鉴别诊断。

核心结论

  • IVIM-DWI在淋巴结转移诊断中是可行的。
  • 恶性淋巴结D值显著降低,反映核质比增高;D*值显著升高,反映血管生成增加和实质灌注增加。

研究设计与样本

  • 回顾性研究,纳入29例头颈部鳞状细胞癌患者和20例淋巴结增生患者。
  • 均行MR检查,IVIM-DWI采用13个b值。
  • 由两名放射科医师独立测量D、D*、f和ADC值,比较两组间差异,并用ROC曲线评价ADC、D、D*和D·D*的诊断价值。

诊断标准与关键数值

  • 头颈部鳞状细胞癌组33枚恶性淋巴结与淋巴结增生组22枚良性淋巴结(最小直径≥5mm)成功检查。
  • 恶性淋巴结ADC(P<0.05)、D(P<0.01)和f(P<0.01)显著低于良性淋巴结,D*显著高于良性淋巴结(P<0.01)。
  • D·D*的AUC为0.983,大于D*的0.952、D的0.78和ADC的0.67。

临床应用与阅片要点

  • 作者认为IVIM-DWI在淋巴结转移诊断中是可行的,D值降低反映核质比增高,D*值升高反映血管生成和实质灌注增加。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the value of pure molecular diffusion(D), perfusion-related diffusion (D*), perfusion fraction (f) and apparent diffusion coefficient (ADC) based on intravoxel incoherent motion (IVIM) theory for differential diagnosis of metastatic lymph nodes (LNs) in head and neck squamous cell carcinoma(HNSCC).

MATERIALS AND METHODS: 29 patients with HNSCC and 20 patients with lymph node hyperplasia (LNH) were enrolled in this retrospective study, underwent magnetic resonance (MR) examination. IVIM Diffusion-weighted imaging (IVIM-DWI) was performed with 13 b values. D, D*, f and ADC values were compared between two groups. The diagnostic value of ADC, D, D* and D·D* value were evaluated by Receiver operating characteristic (ROC) curve. Two radiologists measured D, D*, f and ADC values independently.

RESULTS: 33 malignant LNs in HNSCC group and 22 benign LNs in LNH group (minimum diameter, ≥5mm) were successfully examined, ADC(P<0.05), D (P<0.01) and f (P<0.01) were significantly lower in malignant LNs than that in benign LNs, whereas D* was significantly higher (P<0.01). The area under the ROC curve (AUC) for D·D* was 0.983 and was larger than that for D* (0.952), D (0.78) and ADC (0.67).

CONCLUSION: Our results indicate that IVIM DWI is feasible in the diagnosis of LN metastasis. D was significantly decreased in malignant LNs reflected increased nuclear-to-cytoplasmic ratio tissue, and D* was significantly increased reflected increased blood vessel generation and parenchymal perfusion in malignant LNs.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liang L, Luo X, Lian Z, et al. Lymph node metastasis in head and neck squamous carcinoma: Efficacy of intravoxel incoherent motion magnetic resonance imaging for the differential diagnosis. Eur J Radiol. 2017. PMID: 28583628. doi:10.1016/j.ejrad.2017.02.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。