三维脉冲连续动脉自旋标记灌注MR成像用于豆纹动脉供血区分支动脉粥样硬化病急性脑梗死
研究纳入23例豆纹动脉供血区分支动脉粥样硬化病患者,行DWI、3D-TOF-MRA和3D动脉自旋标记成像,测量病灶区CBF不对称指数、对侧小脑半球不对称指数及DWI梗死体积,并与初始NIHSS评分相关分析。结果显示对侧小脑半球不对称指数和DWI梗死体积与NIHSS评分显著相关,而病灶区CBF不对称指数无相关性。
要点
- 3D动脉自旋标记可检测分支动脉粥样硬化病患者的交叉性小脑神经机能联系不能。
- 对侧小脑半球不对称指数与初始NIHSS评分显著相关(r=0.515,P=.012)。
- DWI梗死体积与初始NIHSS评分显著相关(r=0.664,P=.001)。
核心结论
- 在分支动脉粥样硬化病患者中,3D动脉自旋标记可检测交叉性小脑神经机能联系不能,且其与神经功能严重程度相关。
研究设计与样本
- 研究纳入23例豆纹动脉供血区分支动脉粥样硬化病患者,所有患者行MR成像包括DWI、3D-TOF-MRA和3D-动脉自旋标记;测量病灶区CBF不对称指数、对侧小脑半球不对称指数及DWI梗死体积,并与初始NIHSS评分行Pearson相关分析。
关键影像表现/征象
- 3D动脉自旋标记可显示对侧小脑半球灌注不对称,即交叉性小脑神经机能联系不能。
- 病灶区CBF不对称指数与NIHSS评分无相关性(r=-0.027,P=.724)。
诊断标准与关键数值
- 对侧小脑半球不对称指数与初始NIHSS评分显著相关(r=0.515,P=.012)。
- DWI梗死体积与初始NIHSS评分显著相关(r=0.664,P=.001)。
临床应用与阅片要点
- 3D动脉自旋标记可检测交叉性小脑神经机能联系不能,该征象与神经功能严重程度相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Branch atheromatous disease is a stroke subtype considered a risk factor for early neurologic deterioration. Meanwhile, crossed cerebellar diaschisis is thought to be influenced by the degree and location of supratentorial perfusion abnormalities and is associated with the clinical outcome in the case of an ischemic stroke. In this article, our aim was to clarify the utility of using a whole-brain 3D pulsed continuous arterial spin-labeling method as an imaging biomarker for predicting neurologic severity in branch atheromatous disease.
MATERIALS AND METHODS: Twenty-three patients with branch atheromatous disease in the lenticulostriate artery territory were enrolled. All patients underwent MR imaging, including DWI, 3D-TOF-MRA, and 3D-arterial spin-labeling. We measured the asymmetry index of CBF in the affected area (branch atheromatous disease), the asymmetry index of the contralateral cerebellar hemisphere (crossed cerebellar diaschisis), and the DWI infarct volume in the lenticulostriate artery territory. We also compared each parameter with the initial NIHSS score with the Pearson correlation coefficient.
RESULTS: Among the 23 patients, we found no correlation between NIHSS score and the asymmetry index of CBF in the affected area (branch atheromatous disease) (r = -0.027, P = .724), whereas the asymmetry index of the contralateral cerebellar hemisphere (crossed cerebellar diaschisis) and DWI infarct volumes were significantly correlated with NIHSS score (r = 0.515, P = .012; r = 0.664, P = .001, respectively).
CONCLUSIONS: In patients with branch atheromatous disease, 3D-arterial spin-labeling can detect crossed cerebellar diaschisis, which is correlated with the degree of neurologic severity.
引用
- Shinohara Y, Kato A, Kuya K, et al. Perfusion MR Imaging Using a 3D Pulsed Continuous Arterial Spin-Labeling Method for Acute Cerebral Infarction Classified as Branch Atheromatous Disease Involving the Lenticulostriate Artery Territory. AJNR Am J Neuroradiol. 2017. PMID: 28596191. doi:10.3174/ajnr.A5247
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。