基于高频功率的扩散加权成像在预测神经上皮肿瘤分级中的诊断价值
该回顾性研究纳入115例患者,在3.0-T MRI系统上采集全脑DWI数据(b0和b1000图像),比较基于高频功率(HFP)与最小表观扩散系数(MinADC)在预测神经上皮肿瘤分级中的诊断价值。结果显示HFP在区分低级别与高级别胶质瘤时AUC达1,高于MinADC的AUC 0.83±0.04,除G1与G2组间外,HFP在各组间的鉴别能力均优于MinADC。作者结论认为HFP可作为一种简单有效的工具用于常规临床实践中基于DWI的神经上皮肿瘤分级预测。
要点
- HFP与神经上皮肿瘤分级呈正相关,可用于预测肿瘤分级。
- HFP在区分低级别与高级别胶质瘤时AUC为1,诊断效能良好。
- HFP有助于脑肿瘤边界的选取。
核心结论
- HFP可作为一种简单有效的工具,用于常规临床实践中基于扩散加权图像的神经上皮肿瘤分级预测。
研究设计与样本
- 回顾性研究,纳入115例患者,采用3.0-T MRI系统采集全脑DWI数据(含b0和b1000图像),通过基于MATLAB平台的自编脚本计算HFP值和MinADC值。
诊断标准与关键数值
- HFP在区分低级别胶质瘤(LGG)与高级别胶质瘤(HGG)时AUC值为1;MinADC的AUC为0.83±0.04;HFP在各组间比较中除G1与G2组间(P=0.309)外均有显著差异,MinADC在各组间均有显著差异;除G1与G2组间外,HFP在各组间的鉴别能力均高于MinADC。
临床应用与阅片要点
- 作者认为HFP可作为一种简单有效的工具用于常规临床实践中基于DWI的神经上皮肿瘤分级预测,并有助于脑肿瘤边界的选取。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To retrospectively evaluate the diagnostic value of high-frequency power (HFP) compared with the minimum apparent diffusion coefficient (MinADC) in the prediction of neuroepithelial tumour grading.
METHODS: Diffusion-weighted imaging (DWI) data were acquired on 115 patients by a 3.0-T MRI system, which included b0 images and b1000 images over the whole brain in each patient. The HFP values and MinADC values were calculated by an in-house script written on the MATLAB platform.
RESULTS: There was a significant difference among each group excluding grade I (G1) vs. grade II (G2) (P = 0.309) for HFP and among each group for MinADC. ROC analysis showed a higher discriminative accuracy between low-grade glioma (LGG) and high-grade glioma (HGG) for HFP with area under the curve (AUC) value 1 compared with that for MinADC with AUC 0.83 ± 0.04 and also demonstrated a higher discriminative ability among the G1-grade IV (G4) group for HFP compared with that for MinADC except G1 vs. G2.
CONCLUSIONS: HFP could provide a simple and effective optimal tool for the prediction of neuroepithelial tumour grading based on diffusion-weighted images in routine clinical practice.
KEY POINTS: • HFP shows positive correlation with neuroepithelial tumour grading. • HFP presents a good diagnostic efficacy for LGG and HGG. • HFP is helpful in the selection of brain tumour boundary.
引用
- Chen Z, Zhou P, Lv B, et al. The diagnostic value of high-frequency power-based diffusion-weighted imaging in prediction of neuroepithelial tumour grading. Eur Radiol. 2017. PMID: 28608161. doi:10.1007/s00330-017-4899-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。