文献速递神经MR

人脑T1ρ加权动态葡萄糖增强MR成像

T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.
PubMed 文献 · Radiology · 2017-06-16

这项前瞻性研究纳入9例新诊断胶质母细胞瘤患者和4名健康志愿者,在7.0 T下行T1ρ加权动态葡萄糖增强MR成像,时间分辨率约7秒。健康志愿者基底节灰质DGEρ中位数4.59%显著高于白质0.65%(P=0.028);患者肿瘤强化区DGEρ中位数2.02%显著高于对侧正常表现白质0.08%(P<.0001)。

要点

  • 7.0 T T1ρ加权DGE成像时间分辨率约7秒,可显示脑内葡萄糖增强。
  • 健康志愿者基底节灰质DGEρ 4.59%高于白质0.65%(P=0.028)。
  • 胶质母细胞瘤强化区DGEρ 2.02%高于对侧正常表现白质0.08%(P<.0001)。

核心结论

  • T1ρ加权DGE MR成像在健康志愿者和新诊断未治疗胶质母细胞瘤患者中可显示脑葡萄糖生理及病理生理性葡萄糖摄取增加,可能具有提供肿瘤组织葡萄糖代谢信息的潜力。

研究设计与样本

  • 前瞻性研究,经机构审查委员会批准,纳入9例新诊断胶质母细胞瘤患者和4名健康志愿者,时间范围为2015年10月至2016年7月,使用7.0 T全身MR设备行绝热制备的化学交换敏感自旋锁定成像,时间分辨率约7秒,经肘静脉注射100 mL 20% d-葡萄糖。

关键影像表现/征象

  • 健康志愿者基底节灰质DGEρ中位数为4.59%,白质为0.65%。
  • 胶质母细胞瘤患者葡萄糖增强肿瘤区DGEρ中位数为2.02%,对侧正常表现白质为0.08%。

诊断标准与关键数值

  • 葡萄糖增强以T1ρ加权MR成像相对信号强度变化(DGEρ)定量评估。
  • 健康志愿者基底节灰质DGEρ 4.59% vs 白质0.65%,P=0.028。
  • 胶质母细胞瘤肿瘤区DGEρ 2.02% vs 对侧正常表现白质0.08%,P<.0001。

临床应用与阅片要点

  • 作者认为T1ρ加权DGE MR成像可能具有提供肿瘤组织葡萄糖代谢信息的潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P < .0001). Conclusion T1ρ-weighted DGE MR imaging in healthy volunteers and patients with newly diagnosed, untreated glioblastoma enabled visualization of brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Paech D, Schuenke P, Koehler C, et al. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain. Radiology. 2017. PMID: 28628422. doi:10.1148/radiol.2017162351

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。