3T高b值扩散加权成像获得的表观扩散系数图在胶质瘤术前评估中与标准b值扩散加权成像的比较
纳入63例胶质瘤患者,术前在3T行多b值DWI并生成ADC1000、ADC2000和ADC3000图,比较高b值ADC图在术前评估胶质瘤分级、Ki-67指数和预后中的价值。结果显示平均ADC3000值鉴别高级别与低级别胶质瘤的AUC最高(0.875),与Ki-67增殖指数的负相关最密切(R=-0.567),且是胶质瘤的独立预后因素(p=0.008)。
要点
- 平均ADC3000值鉴别高级别与低级别胶质瘤的AUC为0.875,高于ADC2000的0.847和ADC1000的0.820。
- 平均ADC3000值与Ki-67增殖指数的负相关最密切(R=-0.567),ADC2000为-0.530,ADC1000为-0.499。
- 平均ADC3000值是胶质瘤的独立预后因素(p=0.008),而ADC1000和ADC2000值不是。
核心结论
- 高b值DWI获得的ADC图可能是术前评估胶质瘤更好的影像生物标志物。
研究设计与样本
- 研究纳入63例胶质瘤患者,术前在3T行多b值DWI并生成ADC1000、ADC2000和ADC3000图,采用ROC曲线分析比较各ADC图鉴别高级别与低级别胶质瘤的AUC,计算Pearson相关系数分析各参数与Ki-67增殖指数的相关性,并用Cox回归进行生存分析。
诊断标准与关键数值
- 平均ADC1000值鉴别高级别与低级别胶质瘤的AUC为0.820,低于平均ADC2000值的0.847和平均ADC3000值的0.875。
- 平均ADC1000值与Ki-67增殖指数的Pearson相关系数R为-0.499,负相关程度弱于平均ADC2000值的-0.530和平均ADC3000值的-0.567。
- 平均ADC3000值是胶质瘤的独立预后因素(p=0.008),平均ADC1000和ADC2000值不是独立预后因素。
临床应用与阅片要点
- 作者认为高b值DWI获得的ADC图可能是术前评估胶质瘤更好的影像生物标志物。
- ADC3000图可能改善高级别与低级别胶质瘤的鉴别。
- 平均ADC3000值与Ki-67指数相关性更密切,且为胶质瘤的独立预后因素。
局限性
- 平均ADC3000值是胶质瘤的独立预后因素,而平均ADC1000和ADC2000值不是。
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess whether ADC maps obtained from high b value DWI were more valuable in preoperatively evaluating the grade, Ki-67 index and outcome of gliomas.
METHODS: Sixty-three patients with gliomas, who underwent preoperative multi b value DWI at 3 T, were enrolled. The ADC1000, ADC2000 and ADC3000 maps were generated. Receiver operating characteristic analyses were conducted to determine the area under the curve (AUC) in differentiating high-grade gliomas (HGG) from low-grade gliomas (LGG). Pearson correlation coefficients (R value) were calculated to investigate the correlation between parameters with the Ki-67 proliferation index. Survival analysis was conducted by using Cox regression.
RESULTS: The AUC of the mean ADC1000 value (0.820) was lower than that of the mean ADC2000 value (0.847) and mean ADC3000 value (0.875) in differentiating HGG from LGG. The R value of the mean ADC1000 value (-0.499) was less negative than that of the mean ADC2000 value (-0.530) and mean ADC3000 value (-0.567). The mean ADC3000 value was an independent prognosis factor for gliomas (p = 0.008), while the mean ADC1000 and ADC2000 values were not.
CONCLUSION: ADC maps obtained from high b value DWI might be a better imaging biomarker in the preoperative evaluation of gliomas.
KEY POINTS: • ADC 3000 maps could improve the differentiation between HGG and LGG. • The mean ADC 3000 value had a closer correlation with the Ki-67 index. • The mean ADC 3000 value was an independent prognosis factor for gliomas.
引用
- Zeng Q, Dong F, Shi F, et al. Apparent diffusion coefficient maps obtained from high b value diffusion-weighted imaging in the preoperative evaluation of gliomas at 3T: comparison with standard b value diffusion-weighted imaging. Eur Radiol. 2017. PMID: 28639047. doi:10.1007/s00330-017-4910-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。