基于3D T1rho成像鉴别脑肿瘤相关水肿

Differentiation of brain tumor-related edema based on 3D T1rho imaging.
PubMed 文献 · Eur J Radiol · 2017-03-30

研究纳入23例新诊断脑肿瘤患者(9例转移瘤、8例低级别胶质瘤、6例胶质母细胞瘤),术前行全脑3D T1ρ成像,测量瘤周非强化T2高信号区及正常白质的平均T1ρ值。转移瘤血管源性水肿的T1ρ值显著高于低级别胶质瘤和胶质母细胞瘤的浸润性水肿(p=0.02和<0.01),而低级别胶质瘤与胶质母细胞瘤的浸润性水肿间T1ρ值无显著差异(p=0.84和0.96)。

要点

  • 瘤周非强化T2高信号区T1ρ值在转移瘤血管源性水肿中显著高于胶质瘤浸润性水肿。
  • 低级别胶质瘤与胶质母细胞瘤的浸润性水肿T1ρ值无显著差异(p=0.84和0.96)。
  • 3D T1ρ成像可能有助于定量鉴别转移瘤与胶质瘤相关水肿。

核心结论

  • 研究显示T1ρ在定量鉴别颅内转移瘤相关水肿与胶质瘤相关水肿方面具有可行性和潜在诊断价值,并可能作为标准MR技术的补充工具进一步表征血管源性和浸润性水肿的病理生理。

研究设计与样本

  • 单中心前瞻性研究?原文未报告研究类型;纳入23例新诊断脑肿瘤患者(9例转移瘤、8例低级别胶质瘤、6例胶质母细胞瘤);术前MR检查包括全脑3D T1ρ成像;在瘤周非强化T2信号高信号区(排除强化和坏死或囊性成分)及正常表现白质测量平均T1ρ值。

关键影像表现/征象

  • 转移瘤周围血管源性水肿的平均T1ρ值显著高于低级别胶质瘤相关浸润性水肿(p=0.02)。
  • 转移瘤周围血管源性水肿的平均T1ρ值显著高于胶质母细胞瘤相关浸润性水肿(p<0.01)。
  • 低级别胶质瘤与胶质母细胞瘤的浸润性水肿T1ρ值无显著差异(p=0.84和0.96)。

临床应用与阅片要点

  • 在瘤周非强化T2高信号区测量T1ρ值,需排除强化及坏死或囊性成分。
  • T1ρ值升高可能提示转移瘤相关血管源性水肿而非胶质瘤相关浸润性水肿。
  • 低级别胶质瘤与胶质母细胞瘤的浸润性水肿T1ρ值无显著差异,不能据此鉴别两者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Cerebral edema associated with brain tumors is an important source of morbidity. Its type depends largely on the capillary ultra-structures of the histopathologic subtype of underlying brain tumor. The purpose of our study was to differentiate vasogenic edema associated with brain metastases and infiltrative edema related to diffuse gliomas using quantitative 3D T1 rho (T1ρ) imaging.

MATERIALS AND METHODS: Preoperative MR examination including whole brain 3D T1ρ imaging was performed in 23 patients with newly diagnosed brain tumors (9 with metastasis, 8 with lower grade glioma, LGG, 6 with glioblastoma, GBM). Mean T1ρ values were measured in regions of peritumoral non-enhancing T2 signal hyperintensity, excluding both enhancing and necrotic or cystic component, and normal-appearing white matter.

RESULTS: Mean T1ρ values were significantly elevated in the vasogenic edema surrounding intracranial metastases when compared to the infiltrative edema associated with either LGG or GBM (p=0.02 and <0.01, respectively). No significant difference was noted between T1ρ values of infiltrative edema between LGG and GBM (p=0.84 and 0.96, respectively).

CONCLUSION: Our study demonstrates the feasibility and potential diagnostic role of T1ρ in the quantitative differentiation between edema related to intracranial metastases and gliomas and as a potentially complementary tool to standard MR techniques in further characterizing pathophysiology of vasogenic and infiltrative edema.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Villanueva-Meyer JE, Barajas RF, Mabray MC, et al. Differentiation of brain tumor-related edema based on 3D T1rho imaging. Eur J Radiol. 2017. PMID: 28629576. doi:10.1016/j.ejrad.2017.03.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。