文献速递儿科影像腹部US

超声在新生儿肛门闭锁出生日检测内瘘的诊断准确性:耻骨上与会阴途径诊断性能比较

Diagnostic Accuracy of Sonography for Detection of a Fistula on the Birth Day in Neonates With an Imperforate Anus: Comparison of Diagnostic Performance Between Suprapubic and Perineal Approaches.
PubMed 文献 · J Ultrasound Med · 2017-05-08

研究纳入46例出生日接受耻骨上与会阴超声的肛门闭锁新生儿(29例低位型、17例中/高位型),手术证实39例存在内瘘、12例无内瘘。会阴途径诊断性能显著优于耻骨上途径(P < .0001),基于两种途径联合的最终诊断准确率超过75%。

要点

  • 会阴途径诊断内瘘的AUC显著高于耻骨上途径(P < .0001)。
  • 耻骨上、会阴及两者联合的敏感度分别为52.9%、75.5%、58.7%。
  • 出生日超声检测内瘘的准确率超过75%,作者推荐联合使用两种途径。

核心结论

  • 出生日超声检测肛门闭锁新生儿内瘘的准确率超过75%,会阴途径诊断性能优于耻骨上途径;作者推荐在评估内瘘时于耻骨上途径基础上加用会阴途径。

研究设计与样本

  • 纳入46例出生日接受耻骨上与会阴超声的肛门闭锁新生儿(29例低位型、17例中/高位型),以手术结果为参考标准;两名盲法放射科医师共识评估两种途径图像。

诊断标准与关键数值

  • 会阴途径诊断内瘘的敏感度75.5%、特异度75.5%、准确率75.5%;耻骨上途径敏感度52.9%、特异度79.4%、准确率79.4%;两种途径联合的敏感度58.7%、特异度78.3%、准确率78.3%。

临床应用与阅片要点

  • 作者推荐在评估内瘘时于耻骨上途径基础上加用会阴途径,因会阴途径诊断性能显著优于耻骨上途径(P < .0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic accuracy of sonography for detection of an internal fistula on the birth day in neonates with an imperforate anus and to compare the diagnostic performance between the suprapubic and perineal approaches.

METHODS: We included 46 neonates with an imperforate anus (29 low type and 17 intermediate/high type) who underwent sonography by both the suprapubic and perineal approaches on the birth day. Thirty-nine neonates had internal fistulas, and 12 did not, as surgically proven. Two blinded radiologists evaluated the suprapubic and perineal sonograms for the presence of the internal fistula in consensus. A final diagnosis of the internal fistula was determined on the basis of the findings of both approaches. A receiver operating characteristic analysis was used to compare the diagnostic performance for detection of an internal fistula between the suprapubic and perineal approaches.

RESULTS: The sensitivity, specificity, and accuracy of the final diagnosis based on the findings of suprapubic, perineal, and both approaches were 52.9%, 79.4%, and 79.4%; 75.5%, 75.5%, and 75.5%; and 58.7%, 78.3%, and 78.3%, respectively. The diagnostic performance of the perineal approach was significantly better than that of the suprapubic approach (P < .0001).

CONCLUSIONS: The diagnostic accuracy of sonography for detection of an internal fistula on the birth day exceeded 75% in neonates with an imperforate anus, and sonography on the birth day is feasible. The perineal approach had superior diagnostic performance over the suprapubic approach. Thus, when evaluating an internal fistula by sonography, we recommend using the perineal approach in addition to the suprapubic approach.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hosokawa T, Yamada Y, Tanami Y, et al. Diagnostic Accuracy of Sonography for Detection of a Fistula on the Birth Day in Neonates With an Imperforate Anus: Comparison of Diagnostic Performance Between Suprapubic and Perineal Approaches. J Ultrasound Med. 2017. PMID: 28480562. doi:10.1002/jum.14227

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。