文献速递骨肌儿科影像技术与安全US

新生儿发育性髋关节发育不良经Pavlik吊带治疗后耻骨-股骨距离减小

The pubo-femoral distance decreases with Pavlik harness treatment for developmental dysplasia of the hip in newborns.
PubMed 文献 · Skeletal Radiol · 2017-05-24

纳入25例发育性髋关节发育不良新生儿(43个发育不良髋),在Pavlik吊带治疗平均93天前后于屈髋约90°下测量冠状面和轴面耻骨-股骨距离(PFD)并评估股骨头覆盖率。治疗后发育不良髋PFD在轴面由6.1±1.8 mm降至3.0±0.7 mm、冠状面由5.9±2.0 mm降至3.0±0.6 mm(均p<0.01),股骨头覆盖率由30.8%升至62.1%,PFD变化与股骨头覆盖率变化显著相关(p<0.001)。

要点

  • 新生儿DDH经Pavlik吊带治疗后,超声PFD在轴面和冠状面均显著减小。
  • PFD减小与股骨头覆盖率提高显著相关,可作为监测治疗的指标。
  • 治疗后发育不良髋与未发育不良髋之间PFD无差异。

核心结论

  • 新生儿DDH经Pavlik吊带治疗后PFD显著减小,且与股骨头覆盖率改善显著相关;PFD可能是监测Pavlik吊带治疗新生儿DDH的可靠工具。

研究设计与样本

  • 研究纳入25例经Pavlik吊带治疗的DDH新生儿(16.7±10.4天;19女6男),其中18例双侧、7例单侧,共43个发育不良髋,7个单侧病例的非发育不良髋用于比较;在屈髋约90°下于冠状面和轴面测量PFD,治疗平均93天前后各测一次,并在冠状面评估股骨头覆盖率。

诊断标准与关键数值

  • 发育不良髋轴面PFD由6.1±1.8 mm降至3.0±0.7 mm(校正差值2.9 mm;p<0.01),冠状面由5.9±2.0 mm降至3.0±0.6 mm(校正差值2.7 mm;p<0.01);股骨头覆盖率由30.8%升至62.1%,股骨头覆盖率与PFD的平均差值显著相关(p<0.001);PFD测量具有较高的观察者内和观察者间一致性。

临床应用与阅片要点

  • 对接受Pavlik吊带治疗的新生儿DDH,可在屈髋约90°下于冠状面和轴面测量PFD并结合冠状面股骨头覆盖率进行监测;治疗后发育不良髋与未发育不良髋之间PFD无差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the evolution of the ultrasonographic pubo-femoral distance (PFD) before and after Pavlik harness treatment for developmental dysplasia of the hip (DDH) in newborns.

PATIENTS AND METHODS: Twenty-five patients (16.7 ± 10.4 days; 19 females, six males) diagnosed with DDH and treated using the Pavlik harness were included. Eighteen patients had bilateral, and seven unilateral DDH, with a total of 43 dysplastic hips. The seven non-dysplastic hips in unilateral cases were used for comparison. The PFD was measured in the coronal and axial planes with the hip flexed to approximately 90°, before and after an average of 93 days of treatment. The femoral head coverage was assessed in the coronal plane, and correlated with PFD values.

RESULTS: In dysplastic hips, the mean PFD decreased from 6.1 ± 1.8 mm to 3.0 ± 0.7 mm in the axial (adjusted difference, 2.9 mm; p < 0.01), and from 5.9 ± 2.0 to 3.0 ± 0.6 mm in the coronal plane (adjusted difference 2.7 mm; p < 0.01). The femoral head coverage increased from 30.8 to 62.1%, and the mean differences of femoral head coverage and PFD were significantly correlated (p < 0.001). There was no difference between treated dysplastic and non-dysplastic hips. There was high intra- and inter-observer agreement for PFD measurements.

CONCLUSION: The PFD decreased significantly after DDH treatment using the Pavlik harness in newborns, and showed significant correlation with the femoral head coverage improvement. PFD might be a reliable tool for monitoring DDH treatment in newborns treated using the Pavlik harness.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Maranho DA, Donati FN, Dalto VF, et al. The pubo-femoral distance decreases with Pavlik harness treatment for developmental dysplasia of the hip in newborns. Skeletal Radiol. 2017. PMID: 28540520. doi:10.1007/s00256-017-2668-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。