文献速递神经介入外周血管DSA

使用单个Pipeline栓塞装置治疗串联性颈内动脉动脉瘤:安全性与有效性评估

Treatment of Tandem Internal Carotid Artery Aneurysms Using a Single Pipeline Embolization Device: Evaluation of Safety and Efficacy.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-05-18

回顾性分析2009至2016年美国3家机构连续接受Pipeline栓塞装置治疗的颈内动脉动脉瘤病例,比较串联组与孤立组。串联组34次手术处理78个动脉瘤,孤立组184次手术处理184个动脉瘤。串联组末次造影随访完全闭塞率88.6% vs 孤立组75.1%(P=0.06);有症状血栓栓塞并发症发生率串联组8.8% vs 孤立组2.7%(P=0.08),差异均未达统计学显著。

要点

  • 串联性颈内动脉动脉瘤可用单个Pipeline栓塞装置治疗,完全闭塞率较高。
  • 串联组末次造影随访完全闭塞率88.6%,孤立组为75.1%,P=0.06,未达统计学显著。
  • 有症状血栓栓塞并发症串联组8.8%、孤立组2.7%,P=0.08,未达统计学显著。

核心结论

  • 单个Pipeline栓塞装置治疗颈内动脉串联性动脉瘤可获得较高的完全闭塞率;有症状血栓栓塞并发症率似乎有升高趋势,但未达统计学显著。

研究设计与样本

  • 回顾性分析2009至2016年美国3家机构连续接受Pipeline栓塞装置治疗的颈内动脉动脉瘤病例,分为串联组与孤立组,比较造影和临床结局。

关键影像表现/征象

  • 两组动脉瘤均主要位于颈内动脉眼动脉旁段,孤立组72.3% vs 串联组78.2%(P=0.53)。
  • 孤立组与串联组中位最大径分别为6.2 mm和6.7 mm。
  • 孤立组184次手术处理184个动脉瘤,中位年龄58岁;串联组34次手术处理78个动脉瘤,中位年龄50.5岁。

诊断标准与关键数值

  • 末次造影随访完全闭塞:孤立组75.1% vs 串联组88.6%(P=0.06)。
  • 有症状血栓栓塞并发症:孤立组2.7% vs 串联组8.8%(P=0.08)。

临床应用与阅片要点

  • 串联性颈内动脉动脉瘤可考虑使用单个Pipeline栓塞装置治疗,完全闭塞率较高。
  • 串联组有症状血栓栓塞并发症率似乎有升高趋势,但未达统计学显著(P=0.08)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Tandem aneurysms are defined as multiple aneurysms located in close proximity on the same parent vessel. Endovascular treatment of these aneurysms has rarely been reported. Our aim was to evaluate the safety and efficacy of a single Pipeline Embolization Device for the treatment of tandem aneurysms of the internal carotid artery.

MATERIALS AND METHODS: A retrospective analysis of consecutive aneurysms treated with the Pipeline Embolization Device between 2009 and 2016 at 3 institutions in the United States was performed. Cases included aneurysms of the ICA treated with a single Pipeline Embolization Device, and they were divided into tandem versus solitary. Angiographic and clinical outcomes were compared.

RESULTS: The solitary group (median age, 58 years) underwent 184 Pipeline Embolization Device procedures for 184 aneurysms. The tandem group (median age, 50.5 years) underwent 34 procedures for 78 aneurysms. Aneurysms were primarily located along the paraophthalmic segment of the ICA in both the single and tandem groups (72.3% versus 78.2%, respectively, P = .53). The median maximal diameters in the solitary and tandem groups were 6.2 and 6.7 mm, respectively. Complete occlusion on the last angiographic follow-up was achieved in 75.1% of aneurysms in the single compared with 88.6%% in the tandem group (P = .06). Symptomatic thromboembolic complications were encountered in 2.7% and 8.8% of procedures in the single and tandem groups, respectively (P = .08).

CONCLUSIONS: Tandem aneurysms of the ICA can be treated with a single Pipeline Embolization Device with high rates of complete occlusion. While there appeared to be a trend toward higher thromboembolic complication rates, this did not reach statistical significance.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Adeeb N, Moore JM, Griessenauer CJ, et al. Treatment of Tandem Internal Carotid Artery Aneurysms Using a Single Pipeline Embolization Device: Evaluation of Safety and Efficacy. AJNR Am J Neuroradiol. 2017. PMID: 28522668. doi:10.3174/ajnr.A5221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。