文献速递外周血管技术与安全US

下肢深静脉多普勒超声定性慢血流:定量评估及与后续深静脉血栓形成相关性的初步评价——一项三级肿瘤中心研究

Qualitative Slow Blood Flow in Lower Extremity Deep Veins on Doppler Sonography: Quantitative Assessment and Preliminary Evaluation of Correlation With Subsequent Deep Venous Thrombosis Development in a Tertiary Care Oncology Center.
PubMed 文献 · J Ultrasound Med · 2017-05-04

回顾性分析975例肿瘤患者下肢静脉多普勒超声,482例定性慢血流、493例正常血流;慢血流组后续深静脉血栓发生率4.36%(21/482)近乎为正常血流组2.23%(11/493)的两倍(P=0.0456),且慢血流组峰值流速更低(P<0.001),3个静脉水平流速之和是区分两组的最佳截断值。

要点

  • 慢血流组后续DVT 4.36%(21/482)近乎为正常血流组2.23%(11/493)的两倍(P=0.0456)。
  • 慢血流组各静脉水平峰值流速均低于正常血流组(P<0.001)。
  • 3个静脉水平流速之和是区分正常与慢血流的最佳截断指标。

核心结论

  • 多普勒超声定性判断的下肢慢静脉血流与定量慢血流准确相关,初步提示肿瘤患者后续DVT发生率轻度升高。

研究设计与样本

  • 经机构审查委员会批准的回顾性研究,连续纳入975例患者(慢血流组482例、正常血流组493例),由2名放射科医师确认主观慢血流且初始无DVT,记录3个水平的峰值流速并随访DVT发生。

关键影像表现/征象

  • 慢血流组峰值静脉流速低于正常血流组(P<0.001)。
  • 发生后续DVT的患者与其各自所在组相比静脉流速无显著差异。

诊断标准与关键数值

  • 以约登指数确定与放射科医师主观慢血流相关的最佳峰值流速截断值。
  • 3个静脉水平流速之和为区分正常与慢静脉血流的最佳截断指标。

临床应用与阅片要点

  • 报告下肢静脉多普勒超声时,可将定性慢血流表现与3个水平峰值流速测量结合记录。
  • 肿瘤患者出现定性慢静脉血流时,提示后续DVT风险可能轻度升高。

局限性

  • 原文自述为初步评价(preliminary evaluation)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine whether the qualitative sonographic appearance of slow deep venous flow in the lower extremities correlates with quantitative slow flow and an increased risk of deep venous thrombosis (DVT) in oncology patients.

METHODS: In this Institutional Review Board-approved retrospective study, we reviewed lower extremity venous Doppler sonographic examinations of 975 consecutive patients: 482 with slow flow and 493 with normal flow. The subjective slow venous flow and absence of initial DVT were confirmed by 2 radiologists. Peak velocities were recorded at 3 levels. Each patient was followed for DVT development. The associations between DVT and the presence of slow venous flow were examined by the Fisher exact test; a 2-sample t test was used for peak velocity and DVT group comparisons. The optimal cutoff peak velocity for correlation with the radiologists' perceived slow flow was determined by the Youden index.

RESULTS: Deep venous thrombosis development in the slow-flow group (21 of 482 [4.36%]) was almost doubled compared with patients who had normal flow (11 of 493 [2.23%]; P = .0456). Measured peak venous velocities were lower in the slow-venous flow group (P < .001). Patients with subsequent DVT did not have a significant difference in venous velocities compared with their respective patient groups. The sum of 3 venous level velocities resulted in the best cutoff for dichotomizing groups into normal versus slow venous flow.

CONCLUSIONS: Qualitative slow venous flow in the lower extremities on Doppler sonography accurately correlates with quantitatively slower flow, and this preliminary evaluation suggests an associated mildly increased rate of subsequent DVT development in oncology patients.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Jensen CT, Chahin A, Amin VD, et al. Qualitative Slow Blood Flow in Lower Extremity Deep Veins on Doppler Sonography: Quantitative Assessment and Preliminary Evaluation of Correlation With Subsequent Deep Venous Thrombosis Development in a Tertiary Care Oncology Center. J Ultrasound Med. 2017. PMID: 28470976. doi:10.1002/jum.14220

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。