肩袖撕裂患者肱二头肌长头腱不稳定的MRI关节造影评估与关节镜对照
回顾性分析101例肩袖撕裂患者的肩关节MR关节造影,以关节镜为参考标准,评估肱二头肌长头腱完整性、位置及肱二头肌滑车结构完整性对诊断长头腱不稳定的价值。单独影像征象诊断价值有限,联合轴位与矢状位长头腱位置及滑车结构完整性可提高准确率。
要点
- 轴位图像诊断长头腱不稳定的敏感度82.6%和73.9%,特异度69.9%和87.7%。
- 矢状位位移征象敏感度73.9%和78.3%,特异度64.4%和61.6%。
- 联合多项影像表现准确率达80.9%和90.5%,敏感度60.9%和86.7%,特异度83.1%和91.8%。
核心结论
- 单独影像表现诊断肩袖撕裂患者长头腱不稳定的作用可能有限,联合评估肱二头肌滑车结构完整性与轴位及矢状位长头腱位置可提高MRA准确率。
研究设计与样本
- 回顾性研究,纳入101例患者,以关节镜所见为标准参考,评估肩关节MR关节造影图像。
关键影像表现/征象
- 评估长头腱完整性,读者1正确分类74.3%(75/101),读者2正确分类66.3%(67/101)。
- 轴位图像上可诊断长头腱不稳定,读者1敏感度82.6%、特异度69.9%,读者2敏感度73.9%、特异度87.7%。
- 矢状位图像位移征象诊断长头腱不稳定,读者1敏感度73.9%、特异度64.4%,读者2敏感度78.3%、特异度61.6%。
- 评估上盂肱韧带完整性,读者1敏感度60.9%、特异度70.4%,读者2敏感度93.3%、特异度75.0%。
诊断标准与关键数值
- 联合不同影像表现评估长头腱不稳定,读者1准确率80.9%、敏感度60.9%、特异度83.1%,读者2准确率90.5%、敏感度86.7%、特异度91.8%。
- 轴位图像上长头腱半脱位或脱位、斜矢状位图像上向下移位作为长头腱不稳定的诊断征象。
- 评估肱二头肌滑车结构(上盂肱韧带、肩袖间隙邻近的冈上肌腱和肩胛下肌腱)完整性。
临床应用与阅片要点
- 诊断长头腱不稳定时,可联合评估轴位与矢状位图像上长头腱位置以及肱二头肌滑车结构完整性。
- 单独依赖某一影像征象诊断长头腱不稳定可能作用有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic value of MR arthrography (MRA) in diagnosing instability of the LHBT in patients with rotator cuff tendon tear.
MATERIALS AND METHODS: The MR arthrograms of 101 patients were retrospectively reviewed and correlated with arthroscopic findings as the standard reference. Images were evaluated for (1) the integrity of the LHBT, (2) the position of the LHBT (subluxation/dislocation on axial images, inferior displacement on oblique sagittal image) and (3) the integrity of the biceps pulley (SGHL, supraspinatus and subscapularis tendon adjacent to the rotator interval).
RESULTS: The integrity of the LHBT was correctly classified in 74.3% (75/101) and 66.3% (67/101) by readers 1 and 2, respectively. The diagnosis of LHBT instability could be made on axial images with a sensitivity of 82.6% and 73.9% and specificity of 69.9% and 87.7%, whereas the displacement sign on sagittal images had a sensitivity of 73.9% and 78.3% and a specificity of 64.4% and 61.6%, respectively. Assessing the integrity of the SGHL had a sensitivity of 60.9 and 93.3% and a specificity of 70.4 and 75.0%, respectively. By combining the different image findings, the accuracy in assessing LHBT instability was 80.9 and 90.5% with a sensitivity of 60.9 and 86.7% and specificity of 83.1 and 91.8%, respectively.
CONCLUSION: Individual image findings may have a limited role in diagnosing LHBT instability in patients with rotator cuff tendon tear. The accuracy of MRA may be improved by assessing the integrity of the biceps pulley structures along with the position of the LHBT on both axial and sagittal images.
引用
- Kang Y, Lee JW, Ahn JM, et al. Instability of the long head of the biceps tendon in patients with rotator cuff tear: evaluation on magnetic resonance arthrography of the shoulder with arthroscopic correlation. Skeletal Radiol. 2017. PMID: 28528385. doi:10.1007/s00256-017-2669-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。