人关节软骨浅层定量脉冲回波超声参数与早期退变所致表面粗糙度、胶原含量或胶原取向变化之间的关系
研究纳入6个人股骨髁的20份国际软骨修复学会评分为0或1级的离体样本,用15 MHz脉冲超声三维扫描系统测量振幅型脉冲回波参数,并以激光显微镜和傅里叶变换红外成像光谱测定表面粗糙度(Rq)、平均胶原含量(A1)和胶原取向(A12)。线性混合效应模型多元回归显示软骨表面时域反射系数(Rc)与Rq和A12有显著决定系数(RLMMm2=0.79),但与A1不相关;Rc似乎是反映早期退变样本胶原排列紊乱而非胶原含量的敏感指标。
要点
- 软骨表面时域反射系数(Rc)与表面粗糙度(Rq)和胶原取向(A12)显著相关(RLMMm2=0.79)。
- Rc与浅层平均胶原含量(A1)不相关,提示其不反映胶原含量。
- Rc似乎是反映早期退变软骨浅层胶原排列紊乱而非胶原含量的敏感指标。
核心结论
- 软骨表面时域反射系数(Rc)与表面粗糙度(Rq)和胶原取向(A12)显著相关(RLMMm2=0.79),但与平均胶原含量(A1)不相关;Rc似乎是反映早期退变样本胶原排列紊乱而非胶原含量的敏感指标。
研究设计与样本
- 离体研究,纳入6个人股骨髁的20份样本,按国际软骨修复学会评分判定为0或1级,使用15 MHz脉冲超声三维扫描系统评估,以激光显微镜和傅里叶变换红外成像光谱测量Rq、A1和A12作为参考。
诊断标准与关键数值
- 线性混合效应模型多元回归显示软骨表面时域反射系数(Rc)与表面粗糙度(Rq)和胶原取向(A12)有显著决定系数(RLMMm2=0.79)。
- Rc与浅层平均胶原含量(A1)不相关。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
We aimed to quantitatively investigate the relationship between amplitude-based pulse-echo ultrasound parameters and early degeneration of the knee articular cartilage. Twenty samples from six human femoral condyles judged as grade 0 or 1 according to International Cartilage Repair Society grading were assessed using a 15-MHz pulsed-ultrasound 3-D scanning system ex vivo. Surface roughness (Rq), average collagen content (A1) and collagen orientation (A12) in the superficial zone of the cartilage were measured via laser microscopy and Fourier transform infrared imaging spectroscopy. Multiple regression analysis with a linear mixed-effects model (LMM) revealed that a time-domain reflection coefficient at the cartilage surface (Rc) had a significant coefficient of determination with Rq and A12 (RLMMm2=0.79); however, Rc did not correlate with A1. Concerning the collagen characteristic in the superficial zone, Rc was found to be a sensitive indicator reflecting collagen disorganization, not collagen content, for the early degeneration samples.
引用
- Kiyan W, Ito A, Nakagawa Y, et al. Relationships Between Quantitative Pulse-Echo Ultrasound Parameters from the Superficial Zone of the Human Articular Cartilage and Changes in Surface Roughness, Collagen Content or Collagen Orientation Caused by Early Degeneration. Ultrasound Med Biol. 2017. PMID: 28499496. doi:10.1016/j.ultrasmedbio.2017.03.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。