桡骨远端骨折切开复位内固定术后:超声检出X线漏诊的内固定排列不良及相关肌腱损伤
3例桡骨远端骨折钢板螺钉内固定术后疼痛患者,X线显示内固定位置正常,超声检出3枚螺钉突出及肌腱损伤,均需手术治疗。作者认为肌骨超声可在X线阴性的有症状患者中检出X线隐匿的内固定并发症,并主张其作为肌骨影像的辅助手段。
要点
- 桡骨远端骨折内固定术后疼痛患者,即使X线显示内固定位置正常,也应加做肌骨超声评估肌腱与内固定。
- 超声可检出X线隐匿的螺钉突出(proud screws)及肌腱损伤,本组3例均经手术处理。
- 作者主张将超声作为肌骨影像的辅助手段,以减少内固定并发症的漏诊或延迟诊治。
核心结论
- 本病例系列提示肌骨超声可用于桡骨远端切开复位内固定术后X线阴性但有症状的患者,检出X线未能识别的内固定排列不良和肌腱损伤。
- 作者认为在其临床实践中,超声是避免漏诊或延迟诊治此类内固定并发症最有用的检查方式。
- 作者主张在开展肌骨影像的任何科室将超声作为辅助手段使用。
研究设计与样本
- 病例系列,纳入3例桡骨远端骨折切开复位内固定术后出现疼痛的患者。
- 每例患者X线均将内固定位置判读为正常,随后行针对性肌骨超声检查。
- 以手术所见为参照,超声发现3枚螺钉突出及肌腱损伤,均需手术治疗。
关键影像表现/征象
- 3例患者X线显示内固定位置正常,超声检出3枚螺钉突出(proud screws)。
- 超声同时检出与螺钉突出相关的肌腱损伤,均需手术治疗。
临床应用与阅片要点
- 对桡骨远端骨折内固定术后疼痛而X线阴性的患者,可行针对性肌骨超声评估肌腱完整性和内固定异常。
- 作者主张将超声作为肌骨影像的辅助手段,以减少内固定并发症的漏诊或延迟诊治。
局限性
- 本文为病例系列,仅纳入3例患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Tendon injury is a known complication of distal radius fracture plate and screw fixation. Targeted musculoskeletal sonography is uniquely capable of assessing both tendon integrity and hardware abnormalities not recognized on radiographs. Each of the 3 patients described presented with pain after an open reduction-internal fixation following a distal forearm fracture. In each patient, radiographic findings, specifically the hardware position, were interpreted as normal. Important radiographically occult observations were subsequently made with sonography, including 3 proud screws and tendon injuries, all of which required surgical treatment. This case series demonstrates the clinical utility of musculoskeletal sonography in symptomatic patients after distal radius open reduction-internal fixation with negative radiographic findings. In our practice, sonography has been the most useful modality for precluding missing or delaying the diagnosis and treatment of these hardware complications. We advocate its use as an adjunct in any department performing musculoskeletal imaging.
引用
- Morgan TA, Piper SL, Lattanza LL, et al. Distal Forearm Fracture Open Reduction-Internal Fixation: Sonographic Detection of Hardware Malalignment and Associated Tendon Injuries Missed by Radiography. J Ultrasound Med. 2017. PMID: 28503753. doi:10.1002/jum.14241
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。