急性膝关节损伤患者半月板磁共振图像自动T2映射
本研究纳入80例拟行前交叉韧带或半月板手术的急性膝伤患者,评估自动分割与T2映射内侧半月板(MM)和外侧半月板(LM)的准确性。自动与手动分割的Dice相似指数在2D-TSE、3D-TSE及T2图上分别为MM 76.4%、84.3%、75.2%,LM 76.4%、85.1%、76.1%,自动与手动T2值强相关(rMM=0.95,rLM=0.97)。作者认为该自动方法有望替代手动T2映射分析并整合入临床工作流程。
要点
- 自动分割与手动分割的Dice相似指数在3D-TSE上最高(MM 84.3%,LM 85.1%)。
- 自动与手动T2值强相关(ICCMM=0.94,ICCLM=0.97)。
- 手动与自动方法均显示撕裂MM的T2值显著高于未撕裂MM(P < .05)。
核心结论
- 该自动方法为半月板手动T2映射分析提供了一种有前景的替代方案,并为整合入临床工作流程带来显著进步。
研究设计与样本
- 研究纳入80例拟行前交叉韧带或半月板手术的急性膝伤患者,行膝关节磁共振成像(多平面2D-TSE或3D-TSE检查、T2映射);自动分割2D-TSE(复合体积)或3D-TSE图像上的半月板并自动分区为前、中、后区,再配准至T2图;在2D-TSE(15例)、3D-TSE(16例)及对应T2图(31例)上计算自动与手动分割的Dice相似指数;计算自动与手动T2值的Pearson及组内相关系数(ICC);在同时具有手动与自动分割的患者子集中,用Wilcoxon秩和检验比较撕裂与未撕裂半月板的T2值。
诊断标准与关键数值
- 自动与手动分割的Dice相似指数:2D-TSE上MM 76.4%、LM 76.4%;3D-TSE上MM 84.3%、LM 85.1%;T2图上MM 75.2%、LM 76.1%。
- 自动与手动T2值的Pearson相关系数:MM r=0.95,LM r=0.97;ICC:MM 0.94,LM 0.97。
- 手动与自动方法均显示撕裂MM的T2值显著高于未撕裂MM(全半月板及其亚区,P < .05)。
- 未撕裂LM的T2值高于未撕裂MM(P < .05)。
临床应用与阅片要点
- 自动分割与T2映射在3D-TSE图像上Dice相似指数高于2D-TSE及T2图。
- 自动与手动T2值强相关,提示自动方法可用于半月板T2定量分析。
- 自动方法复现了手动方法所见的撕裂与未撕裂MM的T2值差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to evaluate the accuracy of an automated method for segmentation and T2 mapping of the medial meniscus (MM) and lateral meniscus (LM) in clinical magnetic resonance images from patients with acute knee injury.
MATERIALS AND METHODS: Eighty patients scheduled for surgery of an anterior cruciate ligament or meniscal injury underwent magnetic resonance imaging of the knee (multiplanar two-dimensional [2D] turbo spin echo [TSE] or three-dimensional [3D]-TSE examinations, T2 mapping). Each meniscus was automatically segmented from the 2D-TSE (composite volume) or 3D-TSE images, auto-partitioned into anterior, mid, and posterior regions, and co-registered onto the T2 maps. The Dice similarity index (spatial overlap) was calculated between automated and manual segmentations of 2D-TSE (15 patients), 3D-TSE (16 patients), and corresponding T2 maps (31 patients). Pearson and intraclass correlation coefficients (ICC) were calculated between automated and manual T2 values. T2 values were compared (Wilcoxon rank sum tests) between torn and non-torn menisci for the subset of patients with both manual and automated segmentations to compare statistical outcomes of both methods.
RESULTS: The Dice similarity index values for the 2D-TSE, 3D-TSE, and T2 map volumes, respectively, were 76.4%, 84.3%, and 75.2% for the MM and 76.4%, 85.1%, and 76.1% for the LM. There were strong correlations between automated and manual T2 values (rMM = 0.95, ICCMM = 0.94; rLM = 0.97, ICCLM = 0.97). For both the manual and the automated methods, T2 values were significantly higher in torn than in non-torn MM for the full meniscus and its subregions (P < .05). Non-torn LM had higher T2 values than non-torn MM (P < .05).
CONCLUSIONS: The present automated method offers a promising alternative to manual T2 mapping analyses of the menisci and a considerable advance for integration into clinical workflows.
引用
- Paproki A, Engstrom C, Strudwick M, et al. Automated T2-mapping of the Menisci From Magnetic Resonance Images in Patients with Acute Knee Injury. Acad Radiol. 2017. PMID: 28551397. doi:10.1016/j.acra.2017.03.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。