文献速递骨肌技术与安全USCT

导航超声测量锁骨长度的验证研究

Validation of Navigation Ultrasound for Clavicular Length Measurement.
PubMed 文献 · Ultrasound Med Biol · 2017-05-19

研究在2012至2013年法医尸检前对38具遗体(中位年龄52.5岁,范围21-78岁)用导航超声测量锁骨长度,评估其信度与效度。导航超声信度高(组内相关系数0.942-0.997),效度好(测量误差1.3%-1.8%,95%一致性界限约±7.5 mm),其评分者内信度与三维重建CT扫描相当。

要点

  • 导航超声测量锁骨长度信度高(ICC 0.942-0.997),评分者内信度与三维重建CT相当。
  • 导航超声效度好,测量误差1.3%-1.8%,95%一致性界限约±7.5 mm。
  • 导航超声可用于锁骨中段骨折术前长度测量及需精确骨肌长度测量的其他领域。

核心结论

  • 导航超声可测量锁骨长度,其评分者内信度与三维重建CT扫描相当,且效度高。
  • 导航超声的应用可能扩展至其他需要精确骨肌长度测量的领域。

研究设计与样本

  • 研究于2012至2013年在法医尸检前进行长度测量,共纳入38具遗体,中位年龄52.5岁(范围21-78岁)。
  • 以尸检前导航超声测量锁骨长度,评估信度(组内相关系数、平均标准误、最小可检测变化)与效度(测量误差、95%一致性界限、Pearson相关系数)。

诊断标准与关键数值

  • 导航超声信度:组内相关系数0.942-0.997,平均标准误0.7-2.9 mm,最小可检测变化2.3-8.1 mm。
  • 导航超声效度:测量误差1.3%-1.8%,95%一致性界限约±7.5 mm,Pearson相关系数R 0.948-0.974。

临床应用与阅片要点

  • 导航超声可用于测量锁骨长度,其评分者内信度与三维重建CT扫描相当,效度高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Accurate clavicular length measurement is considered important for the selection of patients requiring surgical treatment after a midclavicular fracture. As radiographic length measurements can be inaccurate to varying degrees, new measurement methods are needed. Use of novel technology, navigation ultrasound, to deliver accurate measurements seems promising. To examine the reliability and validity of navigation ultrasound for length measurements of the clavicle, a study was performed using length measurements performed before forensic autopsies from 2012 to 2013. In total, 38 bodies with a median age of 52.5 (range: 21-78 y) were included. Navigation ultrasound exhibited high reliability (intra-class correlation coefficient: 0.942-0.997, standard error of the mean: 0.7-2.9 mm, minimal detectable change: 2.3-8.1 mm) and validity (measurement error: 1.3%-1.8%, limits of agreement (95% confidence interval): approximately ± 7.5 mm, Pearson's correlation R: 0.948-0.974). Navigation ultrasound can measure clavicular length with an intra-rater reliability matching that of 3-D rendered computed tomography scans and with high validity. Its use could spread to other fields requiring accurate musculoskeletal length measurements.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Thorsmark Høj A, Villa C, Christensen OM, et al. Validation of Navigation Ultrasound for Clavicular Length Measurement. Ultrasound Med Biol. 2017. PMID: 28533004. doi:10.1016/j.ultrasmedbio.2017.04.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。