三维与二维剪切波弹性成像鉴别乳腺良恶性肿块的诊断性能比较
回顾性分析199例患者205个乳腺病灶,比较二维和三维剪切波弹性成像(SWE)与B型超声鉴别良恶性的诊断性能,以组织病理学为参考标准。恶性肿块在二维和三维SWE上的最大和平均弹性值均显著高于良性肿块(p<0.001)。二维SWE及三维轴位、矢状位SWE的AUC显著高于三维冠状位SWE(p<0.05);三维SWE各切面平均弹性的敏感度均高于二维SWE,而二维和三维轴位SWE的特异度高于三维矢状位和冠状位SWE。二维或三维SWE联合B型超声的特异度、阳性预测值和准确率均显著高于单独B型超声(p<0.05)。
要点
- 三维SWE轴位和矢状位图像诊断性能优于冠状位图像。
- 三维SWE各切面平均弹性的敏感度高于二维SWE(81.9%、87.6%、89.5% vs 70.5%,p<0.05)。
- 二维和三维轴位SWE的特异度高于三维矢状位和冠状位SWE。
核心结论
- 二维SWE及三维SWE轴位和矢状位图像诊断性能优于三维冠状位图像;三维SWE联合B型超声可提高鉴别乳腺良恶性肿块的诊断性能。
研究设计与样本
- 回顾性研究,纳入2014年1月至2016年3月期间199例患者共205个乳腺病灶,均在活检前接受B型超声和SWE检查;以组织病理学为参考标准,并分析恶性肿瘤的免疫组化分型(Luminal A、Luminal B、HER2富集型、三阴性乳腺癌)。
关键影像表现/征象
- 恶性肿块在二维和三维SWE上的最大弹性值和平均弹性值均高于良性肿块,差异有统计学意义(p<0.001)。
诊断标准与关键数值
- 二维SWE、三维轴位SWE和三维矢状位SWE的AUC显著高于三维冠状位SWE(p<0.05)。
- 平均弹性:三维轴位、矢状位、冠状位SWE的敏感度分别为81.9%、87.6%、89.5%,均高于二维SWE的70.5%(p<0.05)。
- 最大弹性:二维SWE和三维轴位SWE的特异度分别为84%、83%,高于三维矢状位SWE的76%和三维冠状位SWE的73%(p<0.05)。
- 平均弹性:二维SWE和三维轴位SWE的特异度分别为85%、81%,高于三维矢状位SWE的68%和三维冠状位SWE的50%(p<0.05)。
- 二维或三维SWE联合B型超声鉴别良恶性病灶的特异度、阳性预测值和准确率均显著高于单独B型超声(p<0.05)。
临床应用与阅片要点
- 在评估乳腺肿块时,可结合二维SWE及三维SWE轴位和矢状位图像,其诊断性能优于三维冠状位图像。
- 对于B型超声BI-RADS 3类和4a类病灶,联合二维或三维SWE参数可提高鉴别良恶性的特异度、阳性预测值和准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the diagnostic performance of three-dimensional (3D) image shear-wave elastography (SWE) for differentiating benign from malignant breast masses compared to two-dimensional (2D) SWE and B-mode ultrasound (US).
MATERIALS AND METHODS: This study consisted of 205 breast lesions from 199 patients who underwent B-mode US and SWE before biopsy from January 2014 to March 2016. Quantitative elasticity values (maximum and mean elasticity, Emax and Emean) obtained from 2D and 3D SWE (axial, sagittal, and coronal images) were reviewed retrospectively, in addition to the histopathological findings including immunohistochemistry profiles (luminal A, luminal B, human epidermal growth factor receptor 2 (HER2)-enriched, and triple-negative breast cancer) in cases of malignancy. Histopathological findings were regarded as the reference standard. The diagnostic performance of each data set was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC) analysis to compare sensitivity and specificity.
RESULTS: Among 205 lesions, 105 (51.22%) were malignant and 100 (48.78%) were benign. Compared to benign masses, malignant masses had higher values of Emax and Emean on both 2D and 3D SWE, the differences of which were statistically significant (p<0.001). The AUCs of 2D, 3D axial, and sagittal SWE were significantly higher than that of 3D coronal SWE (p<0.05). In addition, the sensitivities of axial, sagittal, and coronal 3D SWE were all higher than that of 2D SWE for Emean (81.9%, 87.6%, and 89.5% versus 70.5%, respectively, p<0.05). Conversely, the specificity of 2D and 3D axial SWE was higher than that of 3D sagittal and coronal SWE (Emax, 84%, 83% versus 76%, 73%; Emean, 85%, 81% versus 68%, 50%, respectively, p<0.05). We also assessed changes in Breast Imaging-Reporting and Data System (BI-RADS) category 3 and category 4a lesions by adding each of the parameters for 2D and 3D SWE in B-mode US. The specificity, PPV, and accuracy of combined 2D or combined 3D SWE with B-mode US was statistically higher than that of B-mode US alone for differentiating benign and malignant lesions (p<0.05).
CONCLUSIONS: Among SWE images, 2D SWE, and 3D SWE axial and sagittal images exhibited superior diagnostic performance compared to 3D coronal images. Addition of 3D SWE images to B-mode US improved the diagnostic performance for distinguishing benign from malignant masses.
引用
- Choi HY, Sohn YM, Seo M, et al. Comparison of 3D and 2D shear-wave elastography for differentiating benign and malignant breast masses: focus on the diagnostic performance. Clin Radiol. 2017. PMID: 28526455. doi:10.1016/j.crad.2017.04.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。