文献速递乳腺MR

高风险筛查乳腺磁共振成像的简化方案:对性能指标和BI-RADS评估的影响

An Abbreviated Protocol for High-risk Screening Breast Magnetic Resonance Imaging: Impact on Performance Metrics and BI-RADS Assessment.
PubMed 文献 · Acad Radiol · 2017-05-11

前瞻性配对队列研究纳入1052例高风险女性乳腺MRI,先按简化方案阅片、再立即追加全方案序列阅片。全方案癌症检出率为每1000例13.3例、PPV3为30.4%,追加序列使3.4%病例的最终BI-RADS评估改变,其中多数未改变活检相关的临床处理;简化方案与全方案的敏感度和特异度无显著差异。

要点

  • 简化方案与全方案乳腺MRI的敏感度和特异度无显著差异。
  • 追加全方案序列后仅3.4%病例的最终BI-RADS评估发生改变,多数未改变活检处理。
  • 全方案癌症检出率为每1000例13.3例,PPV3为30.4%。

核心结论

  • 该简化MRI方案试点研究显示在癌症检出方面表现有效,追加全方案信息后BI-RADS评估很少改变,简化方案有望用于高风险女性资源节约型乳腺癌筛查。

研究设计与样本

  • 前瞻性配对队列研究,在学术门诊环境中进行,共回顾1052例高风险乳腺癌女性的MRI病例;先按简化MRI方案阅片,随后立即回顾全诊断方案中的附加序列,记录两种方案的BI-RADS评估、所有改变及判读时间。

诊断标准与关键数值

  • 基于全方案,癌症检出率为每1000例13.3例,PPV3为30.4%。
  • 回顾全方案包含的序列后,3.4%的病例最终BI-RADS评估发生改变,其中多数改变未改变关于活检的临床处理。
  • 简化方案与全方案的敏感度和特异度无显著差异。

临床应用与阅片要点

  • 作者认为简化MRI方案在高风险女性乳腺癌筛查中具有资源节约的潜力。

局限性

  • 原文称本研究为试点研究(pilot study)。
  • 原文结论称简化方案 holds promise,需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Annual breast magnetic resonance imaging (MRI) is recommended to screen high-risk populations for breast cancer, although costs are significant. This study assesses the performance of an abbreviated MRI protocol as a resource-efficient approach for screening patients at high-risk of breast cancer, and assesses whether the abbreviated protocol alters the assigned Breast Imaging Reporting and Data System (BI-RADS) category.

MATERIALS AND METHODS: This is a prospective paired cohort study performed in an academic ambulatory setting. MRI images of women at high risk of breast cancer were reviewed using an abbreviated MRI protocol, followed by an immediate review of additional sequences included in a full diagnostic protocol. BI-RADS assessments, including all changes and interpretation times, were recorded for both the abbreviated and full protocol reviews. Cancer detection rate, positive predictive value 3 (PPV3), sensitivity, and specificity were calculated.

RESULTS: A total of 1052 MRI cases were reviewed. The cancer detection rate was 13.3 per 1000 with a PPV3 of 30.4% based on the full protocol. Review of sequences included in the full protocol resulted in a change in the final BI-RADS assessments in 3.4% of the cases, the majority of which did not change clinical management with respect to biopsy. The sensitivity and specificity of the abbreviated and full protocols were not significantly different.

CONCLUSIONS: This pilot study of an abbreviated MRI protocol demonstrates effective performance in cancer detection. BI-RADS assessments were rarely altered with the additional information afforded by the full protocol. The abbreviated protocol holds promise for resource-efficient breast cancer screening in high-risk women.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Panigrahi B, Mullen L, Falomo E, et al. An Abbreviated Protocol for High-risk Screening Breast Magnetic Resonance Imaging: Impact on Performance Metrics and BI-RADS Assessment. Acad Radiol. 2017. PMID: 28506511. doi:10.1016/j.acra.2017.03.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。