立体定向空心针乳腺活检标记物移位:即刻标记物移位影响因素分析
该回顾性研究分析263例连续患者使用9G真空辅助装置的268枚立体定向活检标记物,35枚(13.1%)移位≥1 cm,范围1-6 cm,均值2.35±1.22 cm;整体脂肪型乳腺密度和乳腺内区活检与移位相关,上位活检入路、局部不均质乳腺密度和T形标记物与无移位显著相关。
要点
- 268枚立体定向活检标记物中35枚(13.1%)移位≥1 cm,9枚(25.7%)移位≥3.5 cm。
- 整体脂肪型乳腺密度(P=0.025)和乳腺内区活检(P=0.031)与标记物移位相关。
- 上位活检入路(P=0.025)、局部不均质乳腺密度和T形标记物(P=0.035)与无标记物移位显著相关。
核心结论
- 多种物理、生物学和病理因素影响标记物移位,总体移位率13%支持研究团队开发抗移位新型活检标记物。
研究设计与样本
- 回顾性研究,2010年8月至2013年7月连续263例患者使用9G真空辅助装置放置268枚立体定向活检标记物,复习乳腺X线摄影评估移位相关因素。
关键影像表现/征象
- 35枚(13.1%)标记物距活检腔移位≥1 cm,范围1-6 cm,均值±标准差2.35±1.22 cm。
- 35枚移位标记物中9枚(25.7%)移位≥3.5 cm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors.
METHODS: This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration.
RESULTS: Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration.
CONCLUSIONS: Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration.
KEY POINTS: • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.