用于致密乳腺女性乳腺癌筛查的简化MRI方案
该回顾性研究纳入356例致密乳腺且乳腺X线摄影阴性的女性,比较简化MRI方案AP-1(FAST联合MIP)、AP-2(AP-1联合DWI)与全诊断方案FDP的筛查效能;三者诊断乳腺癌的敏感度与特异度无显著差异,但AP-1特异度显著低于AP-2和FDP,AP-2与FDP无差异;作者认为简化方案可能高效,FAST与MIP联合DWI有助于提高特异度。
要点
- AP-2(FAST+MIP+DWI)敏感度100%、特异度95.0%,与FDP无显著差异。
- AP-1(FAST+MIP)特异度86.5%,显著低于AP-2(P=0.031)和FDP(P=0.035)。
- AP-1和AP-2平均阅片时间分别为37秒和54秒,FDP为3分25秒。
核心结论
- 简化MRI方案可能在致密乳腺乳腺癌筛查中高效,FAST与MIP联合DWI有助于提高乳腺癌检出特异度。
研究设计与样本
- 回顾性研究,纳入356例致密乳腺且乳腺X线摄影阴性的女性,经南京医科大学伦理委员会批准,所有患者行乳腺MRI全诊断方案(FDP),分别分析AP-1(第一个增强后减影FAST和MIP图像)、AP-2(AP-1联合DWI)与FDP的图像。
诊断标准与关键数值
- 以组织学检查为参考,67例女性中检出67个病灶(18.8%),其中恶性14个、良性53个。
- AP-1、AP-2和FDP诊断乳腺癌的敏感度分别为92.9%、100%和100%。
- AP-1、AP-2和FDP诊断乳腺癌的特异度分别为86.5%、95.0%和96.8%。
- 三种MRI方案诊断乳腺癌无显著差异(P>0.05);AP-1特异度显著低于AP-2(P=0.031)和FDP(P=0.035),AP-2与FDP无差异(P>0.05)。
临床应用与阅片要点
- 作者认为简化MRI方案可能在致密乳腺乳腺癌筛查中高效。
- 作者认为FAST与MIP联合DWI有助于提高乳腺癌检出特异度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the validity of two abbreviated protocols (AP) of MRI in breast cancer screening of dense breast tissue.
MATERIALS AND METHODS: This was a retrospective study in 356 participants with dense breast tissue and negative mammography results. The study was approved by the Nanjing Medical University Ethics Committee. Patients were imaged with a full diagnostic protocol (FDP) of MRI. Two APs (AP-1 consisting of the first post-contrast subtracted [FAST] and maximum-intensity projection [MIP] images, and AP-2 consisting of AP-1 combined with diffusion-weighted imaging [DWI]) and FDP images were analyzed separately, and the sensitivities and specificities of breast cancer detection were calculated.
RESULTS: Of the 356 women, 67 lesions were detected in 67 women (18.8%) by standard MR protocol, and histological examination revealed 14 malignant lesions and 53 benign lesions. The average interpretation time of AP-1 and AP-2 were 37 seconds and 54 seconds, respectively, while the average interpretation time of the FDP was 3 minutes and 25 seconds. The sensitivities of the AP-1, AP-2, and FDP were 92.9, 100, and 100%, respectively, and the specificities of the three MR protocols were 86.5, 95.0, and 96.8%, respectively. There was no significant difference among the three MR protocols in the diagnosis of breast cancer (p > 0.05). However, the specificity of AP-1 was significantly lower than that of AP-2 (p = 0.031) and FDP (p = 0.035), while there was no difference between AP-2 and FDP (p > 0.05).
CONCLUSION: The AP may be efficient in the breast cancer screening of dense breast tissue. FAST and MIP images combined with DWI of MRI are helpful to improve the specificity of breast cancer detection.
引用
- Chen SQ, Huang M, Shen YY, et al. Abbreviated MRI Protocols for Detecting Breast Cancer in Women with Dense Breasts. Korean J Radiol. 2017. PMID: 28458599. doi:10.3348/kjr.2017.18.3.470
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。