添加彩色多普勒超声检测羊水异常及其对围产结局的影响
研究纳入428名待产孕妇,分别用灰阶超声和彩色多普勒超声测量羊水指数和最大羊水暗区垂直深度。彩色多普勒超声测值更低,两种方法一致性一般(AFI κ=0.32,SDP κ=0.28),但未增加对不良围产结局的检出。
要点
- 彩色多普勒超声测得的羊水指数和最大羊水暗区垂直深度均低于灰阶超声。
- 两种方法诊断羊水过少的的一致性一般(AFI κ=0.32,SDP κ=0.28)。
- 彩色多普勒超声诊断羊水过少未增加不良围产结局的检出。
核心结论
- 使用彩色多普勒超声会导致羊水过少过度诊断,似乎并未增加对 destined for adverse intrapartum or perinatal outcomes 的妊娠的检出。
研究设计与样本
- 前瞻性研究,纳入428名期待阴道分娩的待产孕妇,先后用灰阶超声和彩色多普勒超声测量羊水指数和最大羊水暗区垂直深度。
关键影像表现/征象
- 彩色多普勒超声估测的羊水体积更低:AFI 灰阶超声 10.7±3.7 cm vs 彩色多普勒超声 8.6±3.6 cm(P<.0001)。
- SDP 灰阶超声 4.6±2.0 cm vs 彩色多普勒超声 3.4±1.4 cm(P<.0001)。
- 灰阶与彩色多普勒超声估测羊水体积的一致性一般,AFI κ=0.32,SDP κ=0.28。
诊断标准与关键数值
- 羊水过少定义为羊水指数小于5 cm或最大羊水暗区垂直深度小于2 cm。
- 彩色多普勒超声诊断羊水过少(灰阶超声正常)与灰阶超声诊断羊水过少(彩色多普勒超声也低)两组比较,围产期复合并发症、分娩方式及新生儿复合并发症均无差异。
临床应用与阅片要点
- 彩色多普勒超声测量羊水指数和最大羊水暗区垂直深度测值低于灰阶超声,可能造成羊水过少过度诊断。
- 彩色多普勒超声诊断的羊水过少未增加对不良围产结局的检出。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine whether color Doppler sonography increases the detection of pregnancies at risk for adverse outcomes.
METHODS: Participants admitted to labor and delivery with the anticipation of a vaginal delivery underwent measurements of amniotic fluid volume (AFV) using amniotic fluid index (AFI) and single deepest pocket (SDP) techniques by grayscale followed by color Doppler sonography. Oligohydramnios was defined as an AFI of less than 5 cm or an SDP of less than 2 cm. Intrapartum and perinatal outcomes were compared between participants with a diagnosis of a low AFV by grayscale and color Doppler sonography.
RESULTS: Over 42 months, 428 women were enrolled in the study. Color Doppler sonography resulted in lower AFV estimates (mean ± SD by the AFI, 10.7 ± 3.7 cm by grayscale sonography and 8.6 ± 3.6cm by color Doppler sonography; P < .0001). For the SDP, the mean AFVs were 4.6 ± 2.0 cm by grayscale sonography and 3.4 ± 1.4 cm by color Doppler sonography (P < .0001). The level of agreement between grayscale and color Doppler sonography in estimating the AFV was fair, with κ = 0.32 for the AFI and 0.28 for the SDP. Outcome measures of AFVs classified as low based on color Doppler sonography (normal by grayscale sonography) and those classified as low by grayscale sonography (low by color Doppler sonography) were compared. There was no difference in composite perinatal complications, mode of delivery, or composite neonatal complications.
CONCLUSIONS: The use of color Doppler sonography leads to the overdiagnosis of low AFVs and does not appear to increase the detection of pregnancies destined for adverse intrapartum or perinatal outcomes.
引用
- Odibo IN, Whittemore BS, Hughes DS, et al. Addition of Color Doppler Sonography for Detection of Amniotic Fluid Disturbances and Its Implications on Perinatal Outcomes. J Ultrasound Med. 2017. PMID: 28503847. doi:10.1002/jum.14223
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。