文献速递妇产影像泌尿生殖MRPET

FDG PET代谢肿瘤体积与ADC直方图预测局部晚期宫颈癌治疗反应及生存的预后价值比较

Comparison of FDG PET metabolic tumour volume versus ADC histogram: prognostic value of tumour treatment response and survival in patients with locally advanced uterine cervical cancer.
PubMed 文献 · Br J Radiol · 2017-06-16

该研究纳入21例接受同步放化疗的局部晚期宫颈癌患者,治疗前行MRI和18F-FDG PET检查,比较PET体积参数与ADC直方图参数在预测治疗反应和事件无生存(EFS)中的价值。结果显示非反应组原发肿瘤的MTV和TLG显著高于反应组,MTV、TLG和10百分位ADC与EFS显著相关。作者认为治疗前18F-FDG PET体积定量参数在预测治疗反应和EFS方面可能优于ADC直方图。

要点

  • 非反应组原发肿瘤MTV和TLG显著高于反应组(p=0.04和p=0.01)。
  • MTV(HR 4.725,p=0.036)、TLG(HR 4.725,p=0.036)和10百分位ADC(HR 5.207,p=0.048)与EFS显著相关。
  • 以最佳截断值分组,MTV和TLG高于截断值者的EFS率显著低于低于截断值者(p=0.002和p=0.002)。

核心结论

  • 治疗前18F-FDG PET体积定量参数在预测局部晚期宫颈癌治疗反应和EFS方面可能优于ADC直方图。

研究设计与样本

  • 研究纳入21例诊断为局部晚期宫颈癌并接受同步放化疗的患者,治疗前均行MRI和18F-FDG PET检查。

诊断标准与关键数值

  • 非反应组原发肿瘤MTV和TLG显著高于反应组(p=0.04和p=0.01)。
  • Cox回归多变量分析显示MTV(HR 4.725,p=0.036)、TLG(HR 4.725,p=0.036)和10百分位ADC(HR 5.207,p=0.048)与EFS有统计学显著关联。
  • 以最佳截断值分组,MTV和TLG高于截断值者的EFS率显著低于低于截断值者(p=0.002和p=0.002)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the prognostic utility of volume-based parameters of fluorine-18 fludeoxyglucose positron emission tomography (18F-FDG PET) and apparent diffusion coefficient (ADC) histogram analysis for tumour response to therapy and event-free survival (EFS) in patients with uterine cervical cancer receiving chemoradiotherapy.

METHODS: The study included 21 patients diagnosed with locally advanced uterine cervical cancer who underwent pre-treatment MRI and 18F-FDG PET and were treated with concurrent chemoradiotherapy. 18F-FDG parameters: maximum and mean standardized uptake value; metabolic tumour volume (MTV); total lesion glycolysis (TLG); ADC parameters: maximum, mean and minimum values; percentile ADC values (10-90%); skewness and kurtosis of ADC were measured and compared between the responder and non-responder groups using a Wilcoxon rank-sum test. The Cox regression analysis and Kaplan-Meier survival curves were performed for EFS analysis.

RESULTS: MTV and TLG of the primary tumour were significantly higher in the non-responder group than in the responder group (p = 0.04 and p = 0.01). Applying Cox regression multivariate analysis, MTV [hazard ratio (HR), 4.725; p = 0.036], TLG (HR, 4.725; p = 0.036) and 10-percentile ADC (HR, 5.207; p = 0.048) showed a statistically significant association with EFS. With the optimal cut-off value, the EFS rates above the cut-off value for MTV and TLG were significantly lower than that below the cut-off value (p = 0.002 and p = 0.002).

CONCLUSION: Pre-treatment volume-based quantitative parameters of 18F-FDG PET may have better potential than ADC histogram for predicting treatment response and EFS in patients with locally advanced cervical cancer. Advances in knowledge: In this study, pre-treatment volume-based quantitative parameters of 18F-FDG PET had better potential than ADC histogram for predicting treatment response and survival in patients with locally advanced cervical cancer.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Ueno Y, Lisbona R, Tamada T, et al. Comparison of FDG PET metabolic tumour volume versus ADC histogram: prognostic value of tumour treatment response and survival in patients with locally advanced uterine cervical cancer. Br J Radiol. 2017. PMID: 28508679. doi:10.1259/bjr.20170035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。