1 T下使用动脉自旋标记MRI定量小鼠肾脏灌注
在1 T桌面磁共振扫描仪上实现基于流动敏感交替反转恢复(FAIR)的动脉自旋标记序列,无需外源性对比剂即可定量小鼠肾脏灌注;测得皮质和髓质灌注分别为402 ± 95和184 ± 52 mL/100 g/min,与文献值一致;注射呋塞米后1小时皮质灌注较基线下降约50%(P < 0.0001),24小时后恢复至基线(P = 0.68)。
要点
- 1 T桌面MRI结合FAIR动脉自旋标记可在不使用外源性对比剂的情况下定量小鼠肾脏灌注。
- 小鼠皮质灌注402 ± 95 mL/100 g/min、髓质灌注184 ± 52 mL/100 g/min,皮髓质血流比值在2至3之间且不依赖小鼠体重。
- 呋塞米注射后1小时皮质灌注较基线下降约50%(P < 0.0001),24小时后恢复至基线(P = 0.68)。
核心结论
- 在1 T桌面扫描仪上成功应用基于FAIR的动脉自旋标记对小鼠肾脏进行无对比剂灌注测量,该序列易于实现,为在屏障后动物设施等有限区域及多模态临床前影像实验室开展纵向灌注研究提供了可能。
研究设计与样本
- 在1 T桌面磁共振扫描仪上使用小鼠体积线圈实现FAIR动脉自旋标记序列,将测得的肾脏灌注结果与正常小鼠文献值比较,并用血管收缩药呋塞米处理的小鼠对技术进行验证。
诊断标准与关键数值
- 小鼠皮质灌注为402 ± 95 mL/100 g/min,髓质灌注为184 ± 52 mL/100 g/min,与文献值一致。
- 皮质与髓质肾血流比值在2至3之间,且不依赖小鼠体重。
- 呋塞米注射后1小时皮质灌注较基线下降约50%(P < 0.0001),24小时后恢复至基线(P = 0.68)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Quantitative measurement of renal perfusion in murine models provides important information on the organ physiology and disease states. The 1-T desktop magnetic resonance imaging has a small footprint and a self-contained fringe field. This resultant flexibility in siting makes the system ideal for preclinical imaging research. Our objective was to evaluate the capability of the 1-T desktop magnetic resonance imaging to measure mouse renal perfusion without the administration of exogenous contrast agents.
MATERIALS AND METHODS: We implemented a flow-sensitive alternating inversion recovery (FAIR)-based arterial spin labeling sequence with a mouse volume coil on a 1-T desktop magnetic resonance scanner. The validity of the implementation was tested by comparing obtained renal perfusion results with literature values for normal mice and challenging the technique with mice treated with furosemide, a blood vessel vasoconstrictor drug.
RESULTS: The measured cortical and medullary perfusions were quantified to be 402 ± 95 and 184 ± 52 mL/100 g/min, respectively, in agreement with literature values. The ratio of cortical to medullary renal blood flow was between 2 and 3 and was independent of the mouse weight. As expected, upon furosemide injection, a decrease (~50%) in cortical perfusion was observed in the mice population, at 1 hour post injection compared to baseline (P < 0.0001), which returned to baseline after 24 hours (P = 0.68).
CONCLUSIONS: We reported the successful application of FAIR-based arterial spin labeling for noncontrast perfusion measurement of mouse kidneys using a 1-T desktop scanner. The easy implementation of FAIR sequence on a 1-T desktop scanner offers the potential for longitudinal perfusion studies in limited access areas such as behind the barrier in mouse facilities and in multimodality preclinical imaging laboratories without the administration of exogenous contrast agents.
引用
- Do QN, Madhuranthakam AJ, Bendel P, et al. Quantification of Mouse Renal Perfusion Using Arterial Spin Labeled MRI at 1 T. Acad Radiol. 2017. PMID: 28495212. doi:10.1016/j.acra.2017.04.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。