文献速递腹部MR

可变密度采样联合压缩感知的自由呼吸动态T1加权成像在钆塞酸二钠增强肝脏磁共振成像中的临床可行性

Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.
PubMed 文献 · Invest Radiol · 2017-01-01

这项回顾性研究纳入51例高呼吸屏气失败风险患者,采用压缩感知重建的容积内插屏气检查(CS-VIBE)加硬门控进行自由呼吸动态T1WI,4名放射科医师按4分制评估图像质量与运动伪影。自由呼吸T1WI总体图像质量在平扫为3.30±0.59,早期动脉期为2.68±0.70,晚期动脉期为2.93±0.65,门静脉期为3.30±0.49;在晚期动脉期图像质量低于3分的13例患者中,呼吸运动分辨重建(XD重建)显著减少运动伪影并改善图像质量。与既往屏气T1WI相比,CS-VIBE在平扫、动脉期和门静脉期显示更少运动伪影和更好图像质量。

要点

  • 自由呼吸CS-VIBE动态T1WI在全部患者中至少一次获得充分的动脉期扫描时机。
  • 晚期动脉期图像质量低于3分的13例患者加做XD重建后运动伪影显著减少、图像质量改善。
  • 与既往屏气T1WI相比,CS-VIBE在平扫、动脉期和门静脉期运动伪影更少、图像质量更好。

核心结论

  • 压缩感知容积内插屏气检查有潜力为高呼吸屏气失败风险患者提供一致的运动校正自由呼吸动态T1WI肝脏MRI。

研究设计与样本

  • 回顾性研究,经本机构审查委员会批准并豁免知情同意,共纳入51例高呼吸屏气失败风险患者,采用CS-VIBE加硬门控行自由呼吸动态T1WI,由4名放射科医师按4分制评估扫描时机、运动伪影和图像质量。

关键影像表现/征象

  • 自由呼吸T1WI总体图像质量评分:平扫3.30±0.59,早期动脉期2.68±0.70,晚期动脉期2.93±0.65,门静脉期3.30±0.49。
  • 13例晚期动脉期图像质量低于3分的患者,XD重建CS-VIBE较未用XD时显著减少运动伪影(P < 0.002-0.021)并改善图像质量(P < 0.0001-0.002)。
  • 与既往屏气T1WI相比,CS-VIBE加硬门控或XD重建在平扫、动脉期和门静脉期运动伪影更少、图像质量更好(P < 0.0001-0.013)。

诊断标准与关键数值

  • 图像质量、运动伪影和扫描时机由4名放射科医师按4分制评分,图像质量低于3分定义为低图像质量。
  • 在68.6%(35/51)既往曾行肝脏MRI的患者中,将CS-VIBE动态期图像质量与运动伪影同既往屏气T1WI进行比较。

临床应用与阅片要点

  • 对高呼吸屏气失败风险患者,可采用自由呼吸CS-VIBE加硬门控行动态T1WI,全部患者至少一次获得充分动脉期扫描时机。
  • 晚期动脉期图像质量低于3分时,可加做XD重建以减少运动伪影并改善图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI).

MATERIALS AND METHODS: This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (<3) on the late arterial phase, respiratory motion-resolved (extradimension [XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs.

RESULTS: In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (<3) on the late arterial phase, motion-resolved reconstructed T1WI (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P < 0.002-0.021) and improved image quality (P < 0.0001-0.002). In comparison with previous BH-T1WI, CS-VIBE with hard gating or XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013).

CONCLUSIONS: Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T1WI for liver MRI in patients at high risk of breath-holding failure.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Yoon JH, Yu MH, Chang W, et al. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing. Invest Radiol. 2017. PMID: 28492418. doi:10.1097/RLI.0000000000000385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。