前列腺多参数磁共振成像:体积与表观扩散系数定量的可重复性
前瞻性研究评估3 T多参数前列腺MRI(使用直肠内线圈)感兴趣区体积和平均ADC的可重复性,15例男性完成两次检查。PI-RADS v2总体评估高度可重复;不同序列体积测量可重复性存在显著差异(P < 0.005);ADC图像上肿瘤ROI平均ADC可重复性优于肿瘤ROI体积(P < 0.05)。
要点
- PI-RADS v2总体评估在两次检查间高度可重复,15例中11例类别完全相同、4例相差1分。
- 外周带肿瘤ROI体积可重复性在不同序列间存在显著差异(P < 0.005)。
- ADC图像上肿瘤ROI平均ADC可重复性优于肿瘤ROI体积(P < 0.05)。
核心结论
- PI-RADS v2总体评估高度可重复;多参数MRI不同序列体积测量可重复性不同;ADC图像上肿瘤ROI平均ADC较肿瘤ROI体积更可重复;前列腺ADC可重复性与其它腹部器官相当。
研究设计与样本
- 前瞻性研究,符合《健康保险可携性和责任法案》,获机构审查委员会批准并签署书面知情同意;共接触189名受试者,40名初步同意,最终15名男性完成两次3 T多参数前列腺MRI(使用直肠内线圈),两次检查间隔2周内;在轴位T2加权、动态对比增强减影和ADC图像上标注全前列腺、整个外周带、正常外周带及疑似肿瘤ROI,并采用PI-RADS v2评估。
诊断标准与关键数值
- 外周带肿瘤ROI体积可重复性系数(RC%)在轴位T2加权为233 mm(71%)、ADC为422 mm(112%)、动态对比增强减影为488 mm(119%);ADC ROI平均RC(RC%)在外周带肿瘤ROI为447 × 10 mm/s(42%)、正常外周带为471 × 10 mm/s(30%)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to evaluate the repeatability of a region of interest (ROI) volume and mean apparent diffusion coefficient (ADC) in standard-of-care 3 T multiparametric magnetic resonance imaging (mpMRI) of the prostate obtained with the use of endorectal coil.
MATERIALS AND METHODS: This prospective study was Health Insurance Portability and Accountability Act compliant, with institutional review board approval and written informed consent. Men with confirmed or suspected treatment-naive prostate cancer scheduled for mpMRI were offered a repeat mpMRI within 2 weeks. Regions of interest corresponding to the whole prostate gland, the entire peripheral zone (PZ), normal PZ, and suspected tumor ROI (tROI) on axial T2-weighted, dynamic contrast-enhanced subtract, and ADC images were annotated and assessed using Prostate Imaging Reporting and Data System (PI-RADS) v2. Repeatability of the ROI volume for each of the analyzed image types and mean ROI ADC was summarized with repeatability coefficient (RC) and RC%.
RESULTS: A total of 189 subjects were approached to participate in the study. Of 40 patients that gave initial agreement, 15 men underwent 2 mpMRI examinations and completed the study. Peripheral zone tROIs were identified in 11 subjects. Tumor ROI volume was less than 0.5 mL in 8 of 11 subjects. PI-RADS categories were identical between baseline-repeat studies in 11/15 subjects and differed by 1 point in 4/15. Peripheral zone tROI volume RC (RC%) was 233 mm (71%) on axial T2-weighted, 422 mm (112%) on ADC, and 488 mm (119%) on dynamic contrast-enhanced subtract. Apparent diffusion coefficient ROI mean RC (RC%) were 447 × 10 mm/s (42%) in PZ tROI and 471 × 10 mm/s (30%) in normal PZ. Significant difference in repeatability of the tROI volume across series was observed (P < 0.005). The mean ADC RC% was lower than volume RC% for tROI ADC (P < 0.05).
CONCLUSIONS: PI-RADS v2 overall assessment was highly repeatable. Multiparametric magnetic resonance imaging sequences differ in volume measurement repeatability. The mean tROI ADC is more repeatable compared with tROI volume in ADC. Repeatability of prostate ADC is comparable with that in other abdominal organs.
引用
- Fedorov A, Vangel MG, Tempany CM, et al. Multiparametric Magnetic Resonance Imaging of the Prostate: Repeatability of Volume and Apparent Diffusion Coefficient Quantification. Invest Radiol. 2017. PMID: 28463931. doi:10.1097/RLI.0000000000000382
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。