一种用于肝脏定量动态增强CT中提取门静脉输入函数的半自动方法
本研究纳入20例接受肝脏灌注CT检查的患者,将动态图像重建为连续薄层,在单幅增强图像上勾画门静脉横截面感兴趣区,并计算投影至所有薄层和所有时间点,得到半自动门静脉输入函数曲线。与常规手动勾画的「金标准」曲线相比,曲线特征和派生药代动力学参数的Bland-Altman图均未显示实质性差异,一致性相关系数分别为0.66–0.98和0.92–0.95。作者结论认为该半自动方法评估肝功能的性能与金标准手动方法相当。
要点
- 在单幅增强图像上勾画门静脉感兴趣区并计算投影,可半自动获得门静脉输入函数曲线。
- 半自动与手动门静脉输入函数曲线的曲线特征一致性相关系数为0.66–0.98。
- 应用合适动力学模型后,派生药代动力学参数的一致性相关系数为0.92–0.95。
核心结论
- 该半自动提取门静脉输入函数的方法在评估肝功能方面与金标准手动方法表现相当。
研究设计与样本
- 研究纳入20例接受肝脏灌注CT检查的患者,将肝脏动态图像重建为连续薄层,以常规手动勾画的门静脉输入函数曲线作为金标准进行对比。
诊断标准与关键数值
- 半自动与手动门静脉输入函数曲线的曲线特征Bland-Altman图未显示实质性差异,一致性相关系数范围为0.66–0.98。
- 应用合适动力学模型后,派生药代动力学参数的Bland-Altman图未显示实质性差异,一致性相关系数范围为0.92–0.95。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To aid the extraction of the portal venous input function (PVIF) from axial dynamic contrast-enhanced CT images of the liver, eliminating the need for full manual outlining of the vessel across time points.
METHODS: A cohort of 20 patients undergoing perfusion CT imaging of the liver was examined. Dynamic images of the liver were reformatted into contiguous thin slices. A region of interest was defined within a transverse section of the portal vein on a single contrast-enhanced image. This region of interest was then computationally projected across all thin slices for all time points to yield a semi-automated PVIF curve. This was compared against the "gold-standard" PVIF curve obtained by conventional manual outlining.
RESULTS: Bland-Altman plots of curve characteristics indicated no substantial difference between automated and manual PVIF curves [concordance correlation coefficient in the range (0.66, 0.98)]. No substantial differences were shown by Bland-Altman plots of derived pharmacokinetic parameters when a suitable kinetic model was applied in each case [concordance correlation coefficient in range (0.92, 0.95)].
CONCLUSION: This semi-automated method of extracting the PVIF performed equivalently to a "gold-standard" manual method for assessing liver function. Advances in knowledge: This technique provides a quick, simple and effective solution to the problems incurred by respiration motion and partial volume factors in the determination of the PVIF in liver dynamic contrast-enhanced CT.
引用
- Gill AB, Hilliard NJ, Hilliard ST, et al. A semi-automatic method for the extraction of the portal venous input function in quantitative dynamic contrast-enhanced CT of the liver. Br J Radiol. 2017. PMID: 28511589. doi:10.1259/bjr.20160875
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。