钆布醇在主动脉上动脉三维时间分辨MR血管成像中的合适最小剂量:与传统单期高分辨率三维增强MR血管成像的比较
本研究纳入462例连续患者,比较标准剂量增强MRA与低剂量时间分辨MRA(分1mL、2mL、3mL三组),发现B组和C组时间分辨MRA图像质量与增强MRA相似,A组较差;动脉狭窄分级与增强MRA相关性极好(R=0.957~0.991),C组时间分辨MRA信噪比高于增强MRA。结论认为低剂量时间分辨MRA可用于评估主动脉上动脉狭窄,可能作为高危人群的替代诊断技术。
要点
- 时间分辨MRA剂量2mL和3mL时图像质量与标准剂量增强MRA相似,1mL时较差。
- 动脉狭窄分级与增强MRA相关性极好,R值随剂量增加而升高(0.957~0.991)。
- 3mL时间分辨MRA信噪比高于增强MRA,1mL和2mL则倾向于较低。
核心结论
- 低剂量时间分辨MRA评估主动脉上动脉狭窄是可行的,可能作为高危人群的替代诊断技术。
研究设计与样本
- 连续纳入462例患者,均行标准剂量增强MRA和低剂量时间分辨MRA,分为A组(时间分辨MRA恒定剂量1mL)、B组(2mL)、C组(3mL);由2名放射科医师独立评估图像质量(5分制,0=失败至4=优秀)、动脉狭窄分级和信噪比,以增强MRA为参考标准。
诊断标准与关键数值
- 动脉狭窄分级标准:0=正常,1=轻度(<30%),2=中度(30%-69%),3=重度至闭塞(≥70%);图像质量5分制(0=失败至4=优秀);时间分辨MRA与增强MRA狭窄分级相关性:A组R=0.957,B组R=0.988,C组R=0.991。
临床应用与阅片要点
- 作者认为低剂量时间分辨MRA可用于评估主动脉上动脉狭窄,并可能作为高危人群的替代诊断技术。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The development of nephrogenic systemic fibrosis and neural tissue deposition is gadolinium dose-dependent. The purpose of this study was to determine the appropriate minimal dose of gadobutrol with time-resolved MRA to assess supra-aortic arterial stenosis with contrast-enhanced MRA as a reference standard.
MATERIALS AND METHODS: Four hundred sixty-two consecutive patients underwent both standard-dose contrast-enhanced MRA and low-dose time-resolved MRA and were classified into 3 groups; group A (a constant dose of 1 mL for time-resolved MRA), group B (2 mL), or group C (3 mL). All studies were independently evaluated by 2 radiologists for image quality by using a 5-point scale (from 0 = failure to 4 = excellent), grading of arterial stenosis (0 = normal, 1 = mild [<30%], 2 = moderate [30%-69%], 3 = severe to occlusion [≥70%]), and signal-to-noise ratio.
RESULTS: The image quality of time-resolved MRA was similar to that of contrast-enhanced MRA in groups B and C, but it was inferior to contrast-enhanced MRA in group A. For the grading of arterial stenosis, there was an excellent correlation between contrast-enhanced MRA and time-resolved MRA (R = 0.957 for group A, R = 0.988 for group B, R = 0.991 for group C). The SNR of time-resolved MRA tended to be lower than that of contrast-enhanced MRA in groups A and B. However, SNR was higher for time-resolved MRA compared with contrast-enhanced MRA in group C.
CONCLUSIONS: Low-dose time-resolved MRA is feasible in the evaluation of supra-aortic stenosis and could be used as an alternative to contrast-enhanced MRA for a diagnostic technique in high-risk populations.
引用
- Bak SH, Roh HG, Moon WJ, et al. Appropriate Minimal Dose of Gadobutrol for 3D Time-Resolved MRA of the Supra-Aortic Arteries: Comparison with Conventional Single-Phase High-Resolution 3D Contrast-Enhanced MRA. AJNR Am J Neuroradiol. 2017. PMID: 28473338. doi:10.3174/ajnr.A5176
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。