文献速递妇产影像儿科影像心血管US

四腔心切面整体球形指数低于第5百分位相关的胎儿异常超声表现

Abnormal Fetal Findings Associated With a Global Sphericity Index of the 4-Chamber View Below the 5th Centile.
PubMed 文献 · J Ultrasound Med · 2017-05-30

本研究在200例20至40周孕龄对照胎儿中测量四腔心切面心外膜舒张末期基底-心尖长度与横径并计算整体球形指数(GSI),在前瞻性检查的300例17至39周孕龄胎儿中评估GSI、Z评分及百分位并与异常超声表现相关。对照胎儿GSI为1.233(SD 0.0953)且不随孕龄变化;研究胎儿中18%(55/300)GSI低于第5百分位(<1.08),其中96%(53/55)伴有其他异常超声表现。结论认为GSI低于第5百分位与胎儿异常超声表现相关。

要点

  • 对照胎儿四腔心切面GSI为1.233(SD 0.0953),且不随孕龄变化。
  • 研究胎儿中18%(55/300)GSI低于第5百分位(<1.08),其中96%(53/55)伴有其他异常超声表现。
  • 估计胎儿体重低于第10百分位的胎儿中,脐动脉多普勒搏动指数高于第95百分位、大脑中动脉搏动指数低于第5百分位、脑胎盘比异常及羊水指数小于5 cm的发生率均显著更高。

核心结论

  • 四腔心切面GSI低于第5百分位与胎儿异常超声表现相关。

研究设计与样本

  • 在200例20至40周孕龄对照胎儿中测量四腔心切面心外膜舒张末期基底-心尖长度与横径计算GSI,并前瞻性检查300例17至39周孕龄研究胎儿,计算GSI、Z评分及百分位。

关键影像表现/征象

  • 对照胎儿GSI为1.233(SD 0.0953),不随孕龄变化。
  • 研究胎儿中18%(55/300)GSI低于第5百分位(<1.08),其中96%(53/55)伴有其他异常超声表现。
  • 心功能障碍胎儿中横径较基底-心尖长度显著增加,与估计胎儿体重无关。

诊断标准与关键数值

  • GSI低于第5百分位定义为<1.08,研究胎儿中该比例18%(55/300),其中96%(53/55)伴有其他异常超声表现。
  • 估计胎儿体重低于第10百分位的胎儿中,脐动脉多普勒搏动指数高于第95百分位的发生率为27% vs 17.7%(P<.05)。
  • 估计胎儿体重低于第10百分位的胎儿中,大脑中动脉多普勒搏动指数低于第5百分位的发生率为27% vs 0%(P<.05)。
  • 估计胎儿体重低于第10百分位的胎儿中,脑胎盘比异常的发生率为27% vs 4.5%(P<.05)。
  • 估计胎儿体重低于第10百分位的胎儿中,羊水指数小于5 cm的发生率为36% vs 9%(P<.05)。

临床应用与阅片要点

  • 四腔心切面测量心外膜舒张末期基底-心尖长度与横径可计算GSI,对照胎儿GSI为1.233(SD 0.0953)且不随孕龄变化。
  • GSI低于第5百分位(<1.08)时,96%(53/55)伴有其他异常超声表现,提示需结合其他超声表现综合评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to evaluate the global sphericity index (GSI) of the 4-chamber view and correlate the results with abnormal ultrasound findings.

METHODS: The epicardial end-diastolic basal-apical length (BAL) and transverse length (TL) of the 4-chamber view were measured to compute the GSI (BAL/TL) in 200 control fetuses between 20 and 40 weeks' gestation. Three hundred study fetuses were prospectively examined between 17 and 39 weeks' gestation. The GSI, Z score, and centile were computed for each of the fetuses.

RESULTS: The GSI (1.233; SD, 0.0953) in the control fetuses was independent of gestational age. Eighteen percent of the study fetuses (55 of 300) had a GSI below the 5th centile (<1.08), of whom 96% (53 of 55) had additional abnormal ultrasound findings. Fetuses with an estimated fetal weight below the 10th centile had a significantly (P < .05) higher rate of an umbilical artery Doppler pulsatility index above the 95th centile (27% versus 17.7%), a middle cerebral artery Doppler pulsatility index below the 5th centile (27% versus 0%), an abnormal cerebroplacental ratio (27% versus 4.5%), and an amniotic fluid index of less than 5 cm (36% versus 9%). The TL was significantly increased compared with the BAL in fetuses with cardiac dysfunction, irrespective of the estimated fetal weight.

CONCLUSIONS: An abnormal GSI below the 5th centile is associated with abnormal fetal ultrasound findings.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. DeVore GR, Satou G, Sklansky M, et al. Abnormal Fetal Findings Associated With a Global Sphericity Index of the 4-Chamber View Below the 5th Centile. J Ultrasound Med. 2017. PMID: 28556937. doi:10.1002/jum.14261

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。