冠状动脉CT血管成像、负荷双能CT灌注与负荷灌注单光子发射计算机断层扫描对冠心病的诊断效能:与有创冠状动脉造影联合负荷灌注心脏磁共振对照
回顾性分析25例疑似冠心病患者,以有创冠状动脉造影(ICA)≥50%狭窄且对应心肌负荷灌注心脏磁共振(SP-CMR)低灌注为参考标准,比较CCTA、DE-CTP、SPECT及CCTA联合灌注成像的诊断效能。血管 Territory 分析中CCTA+DE-CTP的AUC为0.89±0.04,特异度85%且敏感度93%;结论认为CCTA联合DE-CTP可提高特异度而不损失敏感度。
要点
- 血管 Territory 分析:CCTA+DE-CTP的AUC为0.89±0.04,高于CCTA的0.84±0.05和SPECT的0.79±0.06。
- 血管 Territory 分析:CCTA+DE-CTP特异度85%,高于CCTA的72%,敏感度93%略低于CCTA的96%。
- 患者分析:各方法特异度均较低(CCTA 14%、DE-CTP 43%、SPECT 57%、CCTA+DE-CTP 43%、CCTA+SPECT 57%)。
核心结论
- CCTA联合DE-CTP可在不损失敏感度的情况下提高对血流动力学显著冠状动脉狭窄(以ICA联合SP-CMR定义)的特异度。
研究设计与样本
- 回顾性研究,纳入25例疑似冠心病患者,均行CCTA、DE-CTP、SPECT、SP-CMR和ICA;参考标准为ICA显示≥50%狭窄且对应心肌在SP-CMR上存在低灌注。
诊断标准与关键数值
- 参考标准:ICA≥50%狭窄且对应心肌SP-CMR低灌注;血管 Territory 分析敏感度:CCTA 96%、DE-CTP 96%、SPECT 68%、CCTA+DE-CTP 93%、CCTA+SPECT 68%;特异度:CCTA 72%、DE-CTP 75%、SPECT 89%、CCTA+DE-CTP 85%、CCTA+SPECT 94%;AUC:CCTA 0.84±0.05、DE-CTP 0.85±0.05、SPECT 0.79±0.06、CCTA+DE-CTP 0.89±0.04、CCTA+SPECT 0.81±0.06。
临床应用与阅片要点
- 在血管 Territory 分析中,CCTA+DE-CTP较CCTA提高特异度(85% vs 72%)而敏感度略低(93% vs 96%);患者分析中各方法特异度均低(CCTA 14%、DE-CTP 43%、SPECT 57%、CCTA+DE-CTP 43%、CCTA+SPECT 57%),AUC分别为0.57±0.13、0.71±0.11、0.73±0.11、0.71±0.11、0.70±0.11。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard.
MATERIALS AND METHODS: We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR.
RESULTS: For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively.
CONCLUSION: The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.
引用
- Chung HW, Ko SM, Hwang HK, et al. Diagnostic Performance of Coronary CT Angiography, Stress Dual-Energy CT Perfusion, and Stress Perfusion Single-Photon Emission Computed Tomography for Coronary Artery Disease: Comparison with Combined Invasive Coronary Angiography and Stress Perfusion Cardiac MRI. Korean J Radiol. 2017. PMID: 28458600. doi:10.3348/kjr.2017.18.3.476
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。