经导管主动脉瓣置换术前CT血管成像中用于瓣环尺寸测量的最大主动脉瓣开放期相
本研究在50例TAVR术前CTA患者中,由两名读者目测确定最大主动脉瓣开放(MAVO)期相,并比较MAVO期相与常规收缩期(R-R间期35%)的瓣环面积差异。结果显示90%患者MAVO位于R-R间期15%-25%,49/50例瓣环面积在MAVO期相最大,平均差异22.3±4.57 mm²;12%患者因面积差异改变了自膨胀瓣膜推荐尺寸,32%患者会改变球囊扩张瓣膜手术方案。结论认为目测MAVO方法快速且可重复,建议优化CTA采集以支持早期收缩期重建和目测确定MAVO。
要点
- 90%患者MAVO位于R-R间期15%-25%,为早期收缩期。
- 49/50例瓣环面积在MAVO期相最大,与35%期相平均差22.3±4.57 mm²。
- 12%患者瓣环面积差异改变自膨胀瓣膜尺寸,32%会改变球囊扩张瓣膜手术方案。
核心结论
- 目测评估的MAVO多位于早期收缩期,且几乎总是主动脉瓣环面积最大的期相;该方法可快速、可重复地确定TAVR规划测量的适当时相;应考虑优化TAVR术前CT采集以支持早期收缩期重建和目测确定MAVO。
研究设计与样本
- 研究纳入50例患者(平均年龄81岁),由两名读者目测主动脉瓣开放面积确定MAVO期相,并在MAVO期相与典型收缩期(R-R间期35%)测量瓣环面积;比较瓣环面积差异及对瓣膜尺寸选择的影响。
关键影像表现/征象
- 目测确定MAVO期相的观察者间相关性高(0.89)。
- 90%患者MAVO位于R-R间期15%-25%。
- 49/50例患者瓣环面积在MAVO期相最大。
诊断标准与关键数值
- MAVO期相与35%期相的瓣环面积平均差异为22.3±4.57 mm²。
- 12%患者因瓣环面积差异改变了自膨胀瓣膜的推荐尺寸。
- 32%患者因瓣环面积差异会改变球囊扩张瓣膜的手术方案。
临床应用与阅片要点
- 可采用目测主动脉瓣开放面积的方法确定MAVO期相,用于TAVR术前瓣环尺寸测量。
- MAVO期相多位于R-R间期15%-25%,可考虑在早期收缩期重建图像上测量瓣环面积。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The optimal phase for the measurement of the aortic annular area for transcatheter aortic valve replacement (TAVR) is not standardized, although most agree that systolic measurements are preferred, when the annulus is larger. We hypothesized that the maximum annular area occurs at the cardiac phase of the maximum aortic valve opening (MAVO) and that this phase can be accurately and reproducibly assessed by visual inspection only.
MATERIALS AND METHODS: The aortic valve opening area was inspected visually by two readers to determine the MAVO phase. The annular area was measured at the MAVO phase and the typical systolic phase (35% of the R-R interval). Differences in the annular area that would change valve sizing for prostheses were noted.
RESULTS: Fifty patients (mean age 81) were studied. Ninety percent had the MAVO at the 15%-25% R-R interval. There was high interobserver correlation (0.89) for determining the MAVO phase by visual inspection. For 49 out of 50 patients, the annular area was maximal at the MAVO phase. The mean difference in the annular area between the MAVO phase and 35% was 22.3 (±4.57) mm2. In 12% of the patients, the difference in the annular area changed the recommended size of a self-expanding prosthesis and would have altered the procedure in 32% for balloon-expandable prostheses.
CONCLUSIONS: Visually assessed MAVO occurs in early systole for most patients and is almost always the cardiac phase of the maximal aortic annular area. This method allows rapid and reproducible determination of the appropriate phase for TAVR planning measurements. Consideration should be given to optimizing pre-TAVR computed tomography acquisitions for early systolic reconstruction and visual determination of the MAVO.
引用
- Lee NJ, Jha S, Lee BJ, et al. Maximum Aortic Valve Opening Phase for Annulus Sizing in Pre-TAVR CTA. Acad Radiol. 2017. PMID: 28495211. doi:10.1016/j.acra.2017.03.011