支气管镜肺减容术后通气-灌注不匹配的改善:定量影像分析
本研究纳入21例重度肺气肿伴肺过度充气患者,采用氙增强通气与碘增强灌注双能CT评估支气管镜肺减容术(BLVR)前后的通气和灌注变化。结果显示BLVR后FEV1和6分钟步行距离显著改善,每体素通气和总通气均改善,但灌注无显著变化,V/Q不匹配改善主要归因于通气改善。
要点
- BLVR术后每体素通气(P < .001)和总通气(P = .01)均改善,而每体素灌注(P = .16)和总灌注(P = .49)无显著变化。
- 肺减容程度≥50%的患者FEV1改善(P = .02)和每体素通气改善(P = .03)显著优于减容程度<50%的患者。
- BLVR后V/Q不匹配改善(P = .005),主要归因于通气改善。
核心结论
- 双能CT分析显示BLVR改善通气和V/Q不匹配;尽管肺容积减少,肺效率增加可能是BLVR术后改善的主要机制。
研究设计与样本
- 本研究经Asan Medical Center机构审查委员会批准(2013-0368),所有患者签署书面知情同意;纳入21例对常规治疗无反应的重度肺气肿伴肺过度充气患者,在基线及BLVR后3个月行肺功能检查、6分钟步行距离测试、生活质量评估及氙增强通气与碘增强灌注双能CT,采用重复测量方差分析评估BLVR效果。
关键影像表现/征象
- BLVR后FEV1(P < .001)和6分钟步行距离(P = .002)显著改善。
- BLVR后肺容积减少(-0.39 L ± 0.44),但每体素通气(P < .001)和总通气(P = .01)均改善。
- BLVR后每体素灌注(P = .16)和总灌注(P = .49)均无显著变化。
- BLVR后V/Q不匹配改善(P = .005),主要归因于通气改善。
诊断标准与关键数值
- 肺减容程度≥50%的患者FEV1改善(P = .02)和每体素通气改善(P = .03)显著优于减容程度<50%的患者。
临床应用与阅片要点
- 双能CT定量分析可用于评估BLVR术后通气和灌注变化,V/Q不匹配改善主要反映通气改善而非灌注变化。
- 肺减容程度≥50%与更好的FEV1和每体素通气改善相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate whether bronchoscopic lung volume reduction (BLVR) increases ventilation and therefore improves ventilation-perfusion (V/Q) mismatch. Materials and Methods All patients provided written informed consent to be included in this study, which was approved by the Institutional Review Board (2013-0368) of Asan Medical Center. The physiologic changes that occurred after BLVR were measured by using xenon-enhanced ventilation and iodine-enhanced perfusion dual-energy computed tomography (CT). Patients with severe emphysema plus hyperinflation who did not respond to usual treatments were eligible. Pulmonary function tests, the 6-minute walking distance (6MWD) test, quality of life assessment, and dual-energy CT were performed at baseline and 3 months after BLVR. The effect of BLVR was assessed with repeated-measures analysis of variance. Results Twenty-one patients were enrolled in this study (median age, 68 years; mean forced expiratory volume in 1 second [FEV1], 0.75 L ± 0.29). After BLVR, FEV1 (P < .001) and 6MWD (P = .002) improved significantly. Despite the reduction in lung volume (-0.39 L ± 0.44), both ventilation per voxel (P < .001) and total ventilation (P = .01) improved after BLVR. However, neither perfusion per voxel (P = .16) nor total perfusion changed significantly (P = .49). Patients with lung volume reduction of 50% or greater had significantly better improvement in FEV1 (P = .02) and ventilation per voxel (P = .03) than patients with lung volume reduction of less than 50%. V/Q mismatch also improved after BLVR (P = .005), mainly owing to the improvement in ventilation. Conclusion The dual-energy CT analyses showed that BLVR improved ventilation and V/Q mismatch. This increased lung efficiency may be the primary mechanism of improvement after BLVR, despite the reduction in lung volume. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Lee SW, Lee SM, Shin SY, et al. Improvement in Ventilation-Perfusion Mismatch after Bronchoscopic Lung Volume Reduction: Quantitative Image Analysis. Radiology. 2017. PMID: 28510483. doi:10.1148/radiol.2017162148
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。