囊性纤维化肺部表现的MRI:序列评估与临床结局分析
研究纳入28例囊性纤维化患者,对比CT评估多种MRI序列对肺部表现的诊断效能,并分析24个月内肺急性加重。无脂肪抑制PROPELLER序列与CT一致性最高(CCC 0.93),联合该序列、VIBE序列及灌注成像的MRI方案对急性加重次数的相关性与CT相似。
要点
- 无脂肪抑制PROPELLER序列与CT总体Helbich及Eichinger评分一致性最高,CCC均为0.93。
- 含无脂肪抑制PROPELLER、VIBE及灌注成像的MRI方案对肺急性加重次数的相关性与CT相似。
- 其余序列与CT一致性略低:脂肪抑制PROPELLER CCC 0.91/0.92,HASTE 0.87/0.89,VIBE 0.84/0.85。
核心结论
- 囊性纤维化患者最优肺部MRI方案由无脂肪抑制PROPELLER序列、VIBE序列及肺灌注分析组成,可实现高诊断效能与结局预测。
研究设计与样本
- 28例囊性纤维化患者(15男、13女,平均年龄30.5±9.4岁)行胸部CT及1.5 T MRI,MRI包括屏气HASTE、VIBE(增强前后)及呼吸触发PROPELLER(含/不含脂肪抑制)序列和灌注成像,采用改良Helbich和Eichinger评分系统评估,并随访24个月分析肺急性加重。
诊断标准与关键数值
- 无脂肪抑制PROPELLER序列与CT的总体改良Helbich评分一致性相关系数CCC为0.93,总体Eichinger评分CCC为0.93。
- 脂肪抑制PROPELLER序列与CT的CCC分别为0.91(Helbich)和0.92(Eichinger)。
- HASTE序列与CT的CCC分别为0.87(Helbich)和0.89(Eichinger)。
- VIBE序列与CT的CCC分别为0.84(Helbich)和0.85(Eichinger)。
临床应用与阅片要点
- 作者认为囊性纤维化患者最优肺部MRI方案由无脂肪抑制PROPELLER序列、VIBE序列及肺灌注分析组成,以实现高诊断效能和结局预测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate different magnetic resonance imaging (MRI) sequences for diagnosis of pulmonary manifestations of cystic fibrosis (CF) in comparison to chest computed tomography (CT), including an extended outcome analysis.
MATERIALS AND METHODS: Twenty-eight patients with CF (15 male, 13 female, mean age 30.5±9.4 years) underwent CT and MRI of the lung. MRI (1.5 T) included different T2- and T1-weighted sequences: breath-hold HASTE (half Fourier acquisition single shot turbo spin echo) and VIBE (volumetric interpolated breath-hold examination, before and after contrast medium administration) sequences and respiratory-triggered PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) sequences with and without fat signal suppression, and perfusion imaging. CT and MRI images were evaluated by the modified Helbich and the Eichinger scoring systems. The clinical follow-up analysis assessed pulmonary exacerbations within 24 months.
RESULTS: The highest concordance to CT was achieved for the PROPELLER sequences without fat signal suppression (concordance correlation coefficient CCC of the overall modified Helbich score 0.93 and of the overall Eichinger score 0.93). The other sequences had the following concordance: PROPELLER with fat signal suppression (CCCs 0.91 and 0.92), HASTE (CCCs 0.87 and 0.89), VIBE (CCCs 0.84 and 0.85) sequences. In the outcome analysis, the combined MRI analysis of all five sequences and a specific MRI protocol (PROPELLER without fast signal suppression, VIBE sequences, perfusion imaging) reached similar correlations to the number of pulmonary exacerbations as the CT examinations.
CONCLUSION: An optimum lung MRI protocol in patients with CF consists of PROPELLER sequences without fat signal suppression, VIBE sequences, and lung perfusion analysis to enable high diagnostic efficacy and outcome prediction.
引用
- Scholz O, Denecke T, Böttcher J, et al. MRI of cystic fibrosis lung manifestations: sequence evaluation and clinical outcome analysis. Clin Radiol. 2017. PMID: 28545684. doi:10.1016/j.crad.2017.03.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。