文献速递头颈技术与安全CT

头颈癌术后CT预测延迟皮瓣失败的价值

Value of the Post-Operative CT in Predicting Delayed Flap Failures Following Head and Neck Cancer Surgery.
PubMed 文献 · Korean J Radiol · 2017-04-03

回顾性分析60例头颈癌术后皮瓣重建并因怀疑并发症行术后3-14天增强CT的患者,比较延迟皮瓣失败组(需皮瓣修整,n=18)与皮瓣成功组(n=42)的CT表现。CT显示皮瓣内或周围积液>4 cm、积气>2 cm及瘘管在延迟失败组更常见,而皮瓣最大径、脂肪浸润和血管蒂强化与延迟失败无关。

要点

  • 皮瓣内或周围积液>4 cm在延迟失败组占61.1%,成功组占23.8%(p<0.05)。
  • 皮瓣内或周围积气>2 cm在延迟失败组占61.1%,成功组占2.4%(p<0.001)。
  • 通向邻近呼吸道消化道或皮肤的瘘管在延迟失败组占44.4%,成功组占0%(p<0.001)。

核心结论

  • 头颈癌术后怀疑并发症的患者中,大量积液或积气及瘘管是与延迟皮瓣失败相关的CT表现。

研究设计与样本

  • 回顾性研究,纳入60例头颈癌术后皮瓣重建并因怀疑并发症行术后3-14天增强CT的患者,分为延迟皮瓣失败组(需皮瓣修整,n=18)和皮瓣成功组(n=42)。

关键影像表现/征象

  • 皮瓣内或周围积液>4 cm在延迟失败组占61.1%,成功组占23.8%(p<0.05)。
  • 皮瓣内或周围积气>2 cm在延迟失败组占61.1%,成功组占2.4%(p<0.001)。
  • 通向邻近呼吸道消化道或皮肤的瘘管在延迟失败组占44.4%,成功组占0%(p<0.001)。
  • 皮瓣最大径、皮瓣内脂肪浸润和血管蒂强化与延迟皮瓣失败无关。

诊断标准与关键数值

  • 积液>4 cm:延迟失败组61.1% vs 成功组23.8%(p<0.05)。
  • 积气>2 cm:延迟失败组61.1% vs 成功组2.4%(p<0.001)。
  • 瘘管:延迟失败组44.4% vs 成功组0%(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery.

MATERIALS AND METHODS: We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3-14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups.

RESULTS: CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures.

CONCLUSION: A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim B, Yoon DY, Seo YL, et al. Value of the Post-Operative CT in Predicting Delayed Flap Failures Following Head and Neck Cancer Surgery. Korean J Radiol. 2017. PMID: 28458606. doi:10.3348/kjr.2017.18.3.536

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。