弥散加权成像联合动态对比增强MRI鉴别影像学不确定的眶部良恶性肿块
本研究纳入65例眶部肿块患者(良性36例、恶性29例),评估弥散加权成像(DW)与动态对比增强(DCE)MRI联合鉴别影像学不确定的良恶性眶部肿块的价值。恶性组ADC低于良性组、Kep高于良性组,联合ADC与Kep的诊断效能AUC为0.941、敏感度0.966、特异度0.917,联合ADC与Kep的AUC高于单用Kep且有统计学差异(p=0.006),与单用ADC相比AUC更高但差异未达统计学显著(p=0.220)。
要点
- 恶性眶部肿块ADC低于良性、Kep高于良性,ADC与Kep有助于鉴别。
- 联合ADC与Kep诊断效能AUC 0.941、敏感度0.966、特异度0.917。
- 联合ADC与Kep的AUC高于单用Kep(p=0.006),与单用ADC差异未达统计学显著(p=0.220)。
核心结论
- Kep与ADC可帮助鉴别影像学不确定的眶部良恶性肿块,DW与DCE MRI联合可能提高鉴别效能。
研究设计与样本
- 纳入65例眶部肿块患者(良性36例、恶性29例),治疗前接受DW与DCE MRI检查;ADC由DW成像数据用单指数模型得出,Ktrans、Kep、Ve用改良Tofts模型计算;定量指标差异用独立样本t检验,ROC曲线分析确定并比较各显著指标的诊断能力。
诊断标准与关键数值
- 恶性组ADC为0.711±0.260,低于良性组的1.187±0.389(p<0.001)。
临床应用与阅片要点
- 联合ADC与Kep作为诊断指标可获得最佳诊断效能(AUC 0.941;敏感度0.966;特异度0.917)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the performance of the combination of diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for differentiating radiologically indeterminate malignant from benign orbital masses.
MATERIALS AND METHODS: Sixty-five patients with orbital masses (36 benign and 29 malignant) underwent DW and DCE MRI examinations for pre-treatment evaluation. The apparent diffusion coefficient (ADC) was derived from DW imaging data using the mono-exponential model. The volume transfer constant (Ktrans), the flux rate constant between the extravascular extracellular space and the plasma (Kep), and the extravascular extracellular volume fraction (Ve) were calculated using modified Tofts model. Differences in quantitative metrics were tested using independent-samples t test. Receiver operating characteristic (ROC) curve analyses were used to determine and compare the diagnostic ability of each significant metric.
RESULTS: The malignant group demonstrated significantly lower ADC (0.711±0.260 versus 1.187±0.389, p<0.001) and higher Kep values (1.265±0.637 versus 0.871±0.610, p=0.008) than the benign group. Optimal diagnostic performance (area under the ROC curve [AUC], 0.941; sensitivity, 0.966; specificity, 0.917) could be achieved using combined ADC and Kep values as the diagnostic index. The diagnostic performance of the combination of ADC and Kep was significantly better than Kep alone (p=0.006). Compared with ADC alone, combined ADC and Kep values also showed higher AUC (0.941 versus 0.898), although the difference did not reach statistical significance (p=0.220).
CONCLUSION: Kep and ADC could help to differentiate radiologically indeterminate malignant from benign orbital masses. The combination of DW and DCE MRI might improve the differentiating performance.
引用
- Xu XQ, Qian W, Ma G, et al. Combined diffusion-weighted imaging and dynamic contrast-enhanced MRI for differentiating radiologically indeterminate malignant from benign orbital masses. Clin Radiol. 2017. PMID: 28501096. doi:10.1016/j.crad.2017.04.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。