三维超声在原发性甲状旁腺功能亢进症患者术前甲状旁腺评估中的敏感性
回顾性分析52例原发性甲状旁腺功能亢进症患者,比较术前二维超声、三维超声与塞斯塔米比扫描定位异常甲状旁腺的敏感性。三维超声敏感性为88-92%,高于二维超声的69-71%;对小于500 mg的腺体,三维超声敏感性88% vs 二维超声58%(P = .012);三维超声读者间一致性κ = 0.65,优于二维超声的κ = 0.41。
要点
- 三维超声术前定位异常甲状旁腺的敏感性为88-92%,高于二维超声的69-71%。
- 对小于500 mg的腺体,三维超声敏感性88% vs 二维超声58%(P = .012)。
- 三维超声读者间一致性κ = 0.65,优于二维超声的κ = 0.41。
核心结论
- 三维超声对异常甲状旁腺的术前识别敏感性显著高于二维超声,读者间一致性更好,尤其在较小腺体中。
研究设计与样本
- 回顾性研究,纳入2010年1月至2015年4月在本机构单一部位因原发性甲状旁腺功能亢进症行甲状旁腺切除术的52例患者,术前均行二维超声、三维超声和塞斯塔米比扫描,以手术最终腺体定位为参考标准,由两名读者回顾超声图像评估读者间变异。
诊断标准与关键数值
- 三维超声定位腺体的敏感性为88-92%,二维超声为69-71%。
- 当超声与塞斯塔米比扫描将异常定位至同侧时,三维超声敏感性为100%(43/43),二维超声为96%(48/50)。
- 对小于500 mg的腺体,三维超声敏感性88% vs 二维超声58%(P = .012)。
- 三维超声读者间一致性κ = 0.65,二维超声κ = 0.41。
临床应用与阅片要点
- 术前评估异常甲状旁腺时,三维超声对腺体定位的敏感性高于二维超声,尤其对小于500 mg的腺体。
- 三维超声的读者间一致性优于二维超声(κ = 0.65 vs 0.41)。
- 当超声与塞斯塔米比扫描定位至同侧时,三维超声敏感性达100%(43/43)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Preoperative localization of parathyroid adenomas in patients with primary hyperparathyroidism facilitates targeted surgery. We assessed the sensitivity of 3-dimensional (3D) sonography for preoperative localization of abnormal parathyroid glands.
METHODS: We conducted a retrospective review of patients who underwent parathyroidectomy for primary hyperparathyroidism at a single site at our institution. We compared preoperative 2-dimensional (2D) sonography, 3D sonography, and sestamibi scans with final gland localization at surgery. Two readers reviewed the sonograms to assess inter-reader variability.
RESULTS: From January 2010 through April 2015, 52 patients underwent parathyroidectomy after preoperative 2D sonography, 3D sonography, and sestamibi scans. Three-dimensional sonography had sensitivity of 88-92% compared with 69-71% for 2D sonography for gland localization. In patients in whom sonography and sestamibi scans localized abnormalities to the same side, the sensitivities were 100% (43 of 43) for 3D sonography and 96% (48 of 50) for 2D sonography. Three-dimensional sonography had significantly higher sensitivity for localization of glands smaller than 500 mg compared with 2D sonography (88% versus 58%; P = .012). There was better inter-reader agreement between the radiologists when using 3D sonography (κ = 0.65) compared with 2D sonography (κ = 0.41).
CONCLUSIONS: We found a significantly higher sensitivity and better inter-reader agreement for 3D sonography compared with 2D sonography for preoperative identification of abnormal parathyroid glands, especially among smaller glands.
引用
- Frank SJ, Goldman-Yassen AE, Koenigsberg T, et al. Sensitivity of 3-Dimensional Sonography in Preoperative Evaluation of Parathyroid Glands in Patients With Primary Hyperparathyroidism. J Ultrasound Med. 2017. PMID: 28543268. doi:10.1002/jum.14245
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。