高分辨率动态对比增强MRI联合黄金角径向稀疏并行重建在巨腺瘤患者中识别正常垂体腺的作用
回顾性分析17例经蝶窦手术治疗垂体巨腺瘤患者,采用黄金角径向稀疏并行重建的高分辨率动态MRI,基于ROI获取信号-时间曲线和渗透性参数,3名独立阅片者识别正常垂体腺并与术中位置对比。正常垂体腺强化-时间曲线更陡、峰值强化更高(P < .001),观察者间一致性近乎完美(κ = 0.89),14例术中清晰识别者中定位与真实位置相关性近乎完美(κ = 0.95)。
要点
- 正常垂体腺强化-时间曲线较巨腺瘤更陡、峰值强化更高(P < .001),可据此区分。
- 黄金角径向稀疏并行重建动态MRI识别正常垂体腺的观察者间一致性近乎完美(κ = 0.89)。
- 术中清晰识别垂体腺的14例中,阅片者定位与手术真实位置相关性近乎完美(κ = 0.95)。
核心结论
- 本研究证实,采用黄金角径向稀疏并行重建技术结合定量渗透性测量和强化-时间曲线,能够一致且准确地识别巨腺瘤患者的正常垂体腺。
研究设计与样本
- 回顾性研究,纳入17例因垂体巨腺瘤接受经蝶窦手术的患者,采用黄金角径向稀疏并行技术的径向容积插值脑部检查序列,基于ROI方法获取信号-时间曲线和渗透性参数,3名独立阅片者识别正常垂体腺,并与术中垂体腺位置对比。
关键影像表现/征象
- 正常垂体腺的强化-时间曲线较巨腺瘤更陡。
- 正常垂体腺的峰值强化值高于巨腺瘤(P < .001)。
诊断标准与关键数值
- 正常垂体腺与巨腺瘤的强化-时间曲线和峰值强化差异有统计学意义(P < .001)。
- 3个平面观察者间一致性κ = 0.89。
- 14例术中清晰识别垂体腺者中,阅片者定位与手术真实位置一致性κ = 0.95。
临床应用与阅片要点
- 作者指出,利用正常垂体腺强化程度高于巨腺瘤的差异强化模式,高分辨率动态MRI结合黄金角径向稀疏并行重建可用于术前定位垂体腺。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Preoperative localization of the pituitary gland with imaging in patients with macroadenomas has been inadequately explored. The pituitary gland enhancing more avidly than a macroadenoma has been described in the literature. Taking advantage of this differential enhancement pattern, our aim was to evaluate the role of high-resolution dynamic MR imaging with golden-angle radial sparse parallel reconstruction in localizing the pituitary gland in patients undergoing trans-sphenoidal resection of a macroadenoma.
MATERIALS AND METHODS: A retrospective study was performed in 17 patients who underwent trans-sphenoidal surgery for pituitary macroadenoma. Radial volumetric interpolated brain examination sequences with golden-angle radial sparse parallel technique were obtained. Using an ROI-based method to obtain signal-time curves and permeability measures, 3 separate readers identified the normal pituitary gland distinct from the macroadenoma. The readers' localizations were then compared with the intraoperative location of the gland. Statistical analyses were performed to assess the interobserver agreement and correlation with operative findings.
RESULTS: The normal pituitary gland was found to have steeper enhancement-time curves as well as higher peak enhancement values compared with the macroadenoma (P < .001). Interobserver agreement was almost perfect in all 3 planes (κ = 0.89). In the 14 cases in which the gland was clearly identified intraoperatively, the correlation between the readers' localization and the true location derived from surgery was also nearly perfect (κ = 0.95).
CONCLUSIONS: This study confirms our ability to consistently and accurately identify the normal pituitary gland in patients with macroadenomas with the golden-angle radial sparse parallel technique with quantitative permeability measurements and enhancement-time curves.
引用
- Sen R, Sen C, Pack J, et al. Role of High-Resolution Dynamic Contrast-Enhanced MRI with Golden-Angle Radial Sparse Parallel Reconstruction to Identify the Normal Pituitary Gland in Patients with Macroadenomas. AJNR Am J Neuroradiol. 2017. PMID: 28495945. doi:10.3174/ajnr.A5244
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。