文献速递神经儿科影像MR

联合二维与三维MRI序列对儿童脑肿瘤播散性转移的影像学诊断

Radiological diagnosis of drop metastases from paediatric brain tumours using combination of 2D and 3D MRI sequences.
PubMed 文献 · Clin Radiol · 2017-05-22

研究纳入55例初诊儿童原发性脑肿瘤患者,采用包含矢状位2D T1W增强、轴位3D T1W+C VIBE和矢状位3D T2W SPACE的脊髓MRI评估播散性转移。MRI假阴性率为4%,脑脊液假阴性率为16%(p=0.07);3D T1W+C VIBE使42%患者检出更多播散性转移灶,3D T2W SPACE使25%患者病灶更明显。结论认为联合2D与3D序列的脊髓MRI可能改善播散性转移的影像学诊断。

要点

  • 联合2D与3D序列的脊髓MRI诊断儿童脑肿瘤播散性转移的假阴性率为4%。
  • 3D T1W+C VIBE序列使42%患者检出更多播散性转移灶。
  • 3D T2W SPACE序列使25%患者播散性转移灶显示更明显。

核心结论

  • 包含2D与3D序列的脊髓MRI检查表现出可能改善播散性转移影像学诊断的特征。

研究设计与样本

  • 研究纳入55例初诊儿童原发性脑肿瘤患者,采用脊髓MRI评估播散性转移,序列包括矢状位2D T1W增强、轴位3D T1W+C VIBE和矢状位3D T2W SPACE。

关键影像表现/征象

  • 3D T1W+C VIBE使42%患者检出更多播散性转移灶。
  • 3D T2W SPACE使25%患者播散性转移灶显示更明显。

诊断标准与关键数值

  • MRI假阴性率为4%。
  • 脑脊液假阴性率为16%(p=0.07)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate spinal magnetic resonance imaging (MRI) examinations using a combination of two-dimensional (2D) and three-dimensional (3D) MRI sequences for diagnosis of drop metastases.

MATERIALS AND METHODS: Fifty-five paediatric patients with primary brain tumours were evaluated for drop metastases at initial presentation using spinal MRI including sagittal 2D T1-weighted (W) contrast-enhanced (+C), axial 3D T1W+C volumetric interpolated breath-hold (VIBE), and sagittal 3D T2W SPACE (Sampling Perfection with Application optimised Contrasts using different flip angle Evolutions).

RESULTS: The MRI false-negative rate was 4%, and cerebrospinal fluid (CSF) false-negative rate was 16% (p=0.07). The 3D T1W+C VIBE increased the number of drop metastases detected in 42% of patients. Drop metastases were more conspicuous in 25% of patients on 3D T2W SPACE.

CONCLUSION: Spinal MRI examinations including 2D and 3D sequences demonstrate characteristics that may improve radiological diagnosis of drop metastases.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Kralik SF, O'Neill DP, Kamer AP, et al. Radiological diagnosis of drop metastases from paediatric brain tumours using combination of 2D and 3D MRI sequences. Clin Radiol. 2017. PMID: 28545686. doi:10.1016/j.crad.2017.04.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。