在3T和7T下使用加速高分辨率质子磁共振波谱成像绘制扩展的神经化学图谱

Mapping an Extended Neurochemical Profile at 3 and 7 T Using Accelerated High-Resolution Proton Magnetic Resonance Spectroscopic Imaging.
PubMed 文献 · Invest Radiol · 2017-01-01

该研究在10名健康志愿者和2例脑肿瘤患者中比较了3T与7T自由感应衰减磁共振波谱成像(FID-MRSI)。7T下9种代谢物中7种可可靠成像(3T仅3种),信噪比和并行成像效率显著更高,且7T仅需约6分钟即可获得优于3T约30分钟的代谢图。

要点

  • 7T FID-MRSI可在约6分钟内获得全层9种代谢物中7种的可靠高分辨率图谱。
  • 7T下N-乙酰天冬氨酸和谷氨酰胺+谷氨酸的信噪比均显著高于3T。
  • 7T下并行成像效率显著改善,Cramér-Rao下界显著低于3T。

核心结论

  • 在7T下,FID-MRSI可评估扩展的神经化学图谱,并在约6分钟内获得优于3T约30分钟的代谢图;在脑肿瘤中发现了若干可能与治疗相关的神经化学改变,凸显了7T快速临床FID-MRSI的潜力。

研究设计与样本

  • 经机构审查委员会批准的研究,纳入10名健康志愿者(8男/2女,年龄31±6岁)在3T和7T(Trio和7T-Magnetom,Siemens Healthcare,德国)下测量,以及2例脑肿瘤患者(38岁男性和37岁男性,分别为间变性少突星形细胞瘤III级和低级别胶质瘤少突胶质细胞瘤)在7T下测量。

关键影像表现/征象

  • FID-MRSI平面内分辨率为3.4×3.4 mm,在两种场强下非加速/加速采集时间分别为30分钟/6分钟。
  • 7T下9种代谢物中7种可在全层可靠成像,而3T下仅3种。
  • 7T下N-乙酰天冬氨酸信噪比非加速/加速分别提高75%/66%(P<0.05),谷氨酰胺+谷氨酸(Glx)信噪比分别提高97%/74%(P<0.05)。
  • 7T下N-乙酰天冬氨酸半高全宽非加速/加速分别比3T高112%/109%(P<0.05)。
  • 3T下Cramér-Rao下界是7T的两倍以上(P<0.05)。

临床应用与阅片要点

  • 7T FID-MRSI可在约6分钟内获得扩展神经化学图谱,较3T约30分钟显著缩短采集时间。
  • 脑肿瘤中发现的神经化学改变可能与治疗相关,提示7T快速临床FID-MRSI的潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare high-resolution free induction decay magnetic resonance spectroscopic imaging (FID-MRSI) at 3 T and 7 T in the brain of healthy subjects and to showcase the clinical potential of accelerated FID-MRSI at 7 T in 2 brain tumor cases.

MATERIALS AND METHODS: In this institutional review board-approved study, 10 healthy volunteers (8 men/2 women; age: 31 ± 6 years) were measured at 3 T and 7 T (Trio and 7T-Magnetom; Siemens Healthcare, Germany) and 2 patients (a 38-year-old man and a 37-year-old man), 1 with an anaplastic oligoastrocytoma (grade III) and 1 with a low-grade glioma (oligodendroglioma), were measured at 7 T.Free induction decay MR spectroscopic imaging with 3.4 × 3.4 mm in-plane resolution was acquired in 30 minutes/6 minutes (nonaccelerated/accelerated) at both field strengths. In addition, single-slice or multi-slice FID-MRSI at 7 T was measured in the 2 tumor patients at 7 T within 6 minutes/13.3 minutes. Signal-to-noise ratio, Cramer-Rao lower bounds, and parallel imaging efficiency were assessed. High-resolution maps were created for 9 different brain metabolites.

RESULTS: At 7 T, 7 of 9 metabolites were reliably mapped over the whole slice but only 3 at 3 T. Parallel imaging efficiency was significantly improved at 7 T. Signal-to-noise ratios were +75%/+66% (P < 0.05) for N-acetylaspartate and +97%/+74%(P < 0.05) for glutamine + glutamate [Glx], and full-widths at half maximum were +112%/+109%(P < 0.05) higher at 7 T than at 3 T (nonaccelerated/accelerated) for N-acetylaspartate. Cramer-Rao lower bounds were more than double at 3 T (P < 0.05).

CONCLUSIONS: At 7 T, FID-MRSI allowed the assessment of an extended neurochemical profile and yielded better metabolic maps in only approximately 6 minutes at 7 T than in approximately 30 minutes at 3 T. We found several potentially therapy-relevant neurochemical alterations in brain tumors that highlighted the potential of fast clinical FID-MRSI at 7 T.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Gruber S, Heckova E, Strasser B, et al. Mapping an Extended Neurochemical Profile at 3 and 7 T Using Accelerated High-Resolution Proton Magnetic Resonance Spectroscopic Imaging. Invest Radiol. 2017. PMID: 28459799. doi:10.1097/RLI.0000000000000379