磁敏感加权成像评估重型β地中海贫血患者脉络丛铁沉积程度的效用
研究纳入18例输血依赖型β地中海贫血患者及对照组,行MRI检查,采用脉络丛低信号数目(NHICP)分级系统在FSE T2加权、GRE T2*加权和SWI图像上分别评估信号强度。结果显示SWI敏感度0.81,GRE T2*加权0.48,FSE T2加权0.17,三者差异有统计学意义(χ²=74.85,df=2,P<0.0001),SWI最敏感。结论认为SWI有助于显示β地中海贫血患者脑内铁沉积,尤其早期阶段,并可用于预测疾病预后。
要点
- SWI对脉络丛铁沉积的敏感度为0.81,高于GRE T2*加权0.48和FSE T2加权0.17。
- 三种序列显示脉络丛铁沉积的能力差异有统计学意义(χ²=74.85,df=2,P<0.0001)。
- SWI最敏感,有助于显示β地中海贫血患者脑内铁沉积,尤其早期阶段。
核心结论
- SWI有助于显示β地中海贫血患者脑内铁沉积,尤其疾病早期阶段,并可用于预测疾病预后;本研究有助于理解脉络丛在脑铁代谢中的重要作用。
研究设计与样本
- 研究纳入18例输血依赖型β地中海贫血患者及对照组行MRI检查,采用脉络丛低信号数目(NHICP)分级系统在轴位FSE T2加权、GRE T2*加权和SWI图像上分别评估信号强度。
关键影像表现/征象
- 在轴位FSE T2加权、GRE T2*加权和SWI图像上采用脉络丛低信号数目(NHICP)分级系统评估脉络丛信号强度。
- SWI对脉络丛铁沉积的敏感度为0.81,GRE T2*加权为0.48,FSE T2加权为0.17。
- 三种序列显示脉络丛铁沉积的能力差异有统计学意义(χ²=74.85,df=2,P<0.0001),SWI最敏感。
诊断标准与关键数值
- 采用脉络丛低信号数目(NHICP)分级系统在FSE T2加权、GRE T2*加权和SWI图像上评分。
- 敏感度:FSE T2加权=0.17,GRE T2*加权=0.48,SWI=0.81。
- 三种方法敏感度比较:χ²=74.85,df=2,P<0.0001。
临床应用与阅片要点
- 作者认为SWI可用于显示β地中海贫血患者脑内铁沉积,尤其早期阶段,并可用于预测疾病预后。
- 作者认为本研究有助于理解脉络丛在脑铁代谢中的重要作用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess iron accumulation in the choroid plexus of β-thalassaemia patients using fast spin echo (FSE) T2-weighted, gradient echo (GRE) T2*-weighted, susceptibility-weighted imaging (SWI) and compare the results.
MATERIALS AND METHODS: Eighteen patients with transfusion-dependent β-thalassaemia and the control group underwent magnetic resonance imaging (MRI) examinations. Signal intensities were separately evaluated using a "number of hypointensity in the choroid plexus" (NHICP) grading system on axial FSE T2-weighted, GRE T2*-weighted, and SWI images. The NHICP grading system scores were compared using the chi-squared test. Spearman's correlation analysis was used to explore relationships between the variables and NHICP grading system scores.
RESULTS: The sensitivity of each technique was calculated: FSE T2-weighted imaging=0.17, GRE T2*-weighted imaging=0.48, and SWI=0.81. Three-sample test for equality of proportions showed that chi-squared=74.85, df=2, p<0.0001. All of the FSE T2-weighted, GRE T2*-weighted, and SWI images differed significantly in terms of their capacity to reveal iron accumulation in the choroid plexus. Of the three methods, SWI was the most sensitive.
CONCLUSIONS: SWI is useful for revealing iron deposition in the brains of β-thalassaemia patients, especially those in the early stages of disease, and it can be used to predict disease prognosis. The present study contributes to an understanding of the important role played by the choroid plexus in brain iron metabolism.
引用
- Hasiloglu ZI, Asik M, Ure E, et al. The utility of susceptibility-weighted imaging to evaluate the extent of iron accumulation in the choroid plexus of patients with β-thalassaemia major. Clin Radiol. 2017. PMID: 28502664. doi:10.1016/j.crad.2017.04.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。